Protection Vault Note the protection vault details such as protection vault name,
type, credentials to access the location, and passphrase.
To determine which vault is associated to a server perform the
following steps:
1 Select all the servers in Maintenance Center of OMIMSSC
and select import server prole.
2 Select custom import and note down the vault name
associated with the server.
Jobs and Logs Center
• Scheduled jobs
Data of jobs run in DLCI for SCVMM cannot be migrated to
OMIMSSC.
LC logs LC logs collected in DLCI for SCVMM cannot be migrated to
OMIMSSC.
IG share folder les Copy the IG share folder les from DLCI for SCVMM and paste
them in the new IG share folder location.
The default IG path for DLCI for SCVMM is: C:\ProgramData
\DLCI Integration Gateway
The default IG path for OMIMSSC is: C:\ProgramData\OMIMSSC
\Integration Gateway
For more information about user data in DLCI for SCVMM, refer to Dell Lifecycle Controller Integration Version 1.3 for Microsoft System
Center Virtual Machine Manager User Guide.
6
Saving all user data from DLCI for SCVMM