Latest inventory information is not displayed even
after firmware update
Even though the firmware update job is complete on an 11th generation of PowerEdge server, in the Appliance, the inventory
does not display the latest firmware versions.
In the Appliance, refreshing the inventory is an activity performed immediately after a firmware update job is complete. Firmware
update is completed even before the PowerEdge servers CSIOR activity is complete, due to which the earlier firmware
inventory information is displayed.
As a workaround, check if the CSIOR activity is complete in the PowerEdge server, and then in the Appliance, refresh the
firmware inventory. Also, ensure to restart the server after applying agent-free staged update. For more information on
refreshing the inventory, see Viewing and refreshing firmware inventory.
For more information on CSIOR, refer to the Troubleshooting section in the latest version of the Dell Lifecycle Controller GUI
User's Guide available at dell.com/support/home.
SCVMM error 21119 while adding servers to active
directory
While adding servers to Active Directory, SCVMM error 21119 is displayed. Error 21119: The physical computer
with <SMBIOS GUID> did not join Active Directory in time. The comptuer was expected to join
Active Directory using the computer name <host.domain>.
As a workaround, do the following:
1. Wait for some time to see if the server is added to the Active Directory.
2. If the server is not added to the Active Directory, then manually add the servers to the Active Directory.
3. Add the server in to SCVMM.
4. Once the server is added in to SCVMM, rediscover the server in OMIMSSC console extension for SCVMM.
The server will be listed under the Host tab.
Troubleshooting
59