Users Guide

Table Of Contents
Discovering servers and synchronizing with
MSSC console
Discovery is the process of adding supported PowerEdge bare-metal server or host servers in OMIMSSC, and synchronization
with MSSC console allows you to add host servers from SCCM or SCVMM console into OMIMSSC.
Topics:
About reference server configuration
Discovering servers in OMIMSSC
Server discovery in OMIMSSC console extension for SCCM
Server discovery in OMIMSSC console extension for SCVMM
System requirements for managed systems
Discovering servers using auto discovery
Discovering servers using manual discovery
Synchronizing OMIMSSC console extensions with enrolled SCCM
Synchronizing OMIMSSC console extension with enrolled SCVMM
Synchronizing with enrolled MSSC
Resolving synchronization errors
Deleting servers from OMIMSSC
Launching iDRAC console
About reference server configuration
A server configuration with a preferred boot sequence, BIOS, RAID settings, hardware configuration, firmware update
attributes, and operating system parameters that is ideally suited for an organization is called reference server configuration.
Discover a reference server by capturing these settings in an Operational Template, and replicate it across different servers with
same hardware configuration.
Discovering servers in OMIMSSC
You can discover hosts and unassigned servers in OMIMSSC. The discovered servers information is saved in the OMIMSSC
database.
Consider the following points after discovering a server:
The discovered server is added to the Hosts or Unassigned tab in the Configuration and Deployment page of
OMIMSSC.
The discovered server is marked as hardware compatible when it contains supported versions of LC firmware, iDRAC, and
BIOS to work with OMIMSSC. For information about the supported versions, see OpenManage Integration for Microsoft
System Center Release Notes.
A license is consumed for the discovered server.
The Licensed Nodes count in License Center page decreases as the number of servers are discovered.
When you discover a PowerEdge server with an operating system deployed on it, and the server is already present in SCCM
or SCVMM console, then the server is listed as a host server under the Hosts tab in OMIMSSC console extensions where
the discovery job is initiated.
If the host is a modular server, then the service tag of the chassis containing the server is also displayed on the
Configuration and Deployment page.
When you discover a PowerEdge server that is not listed in SCCM or SCVMM, then the server is listed as an unassigned
server under the Unassigned tab in all the enrolled OMIMSSC console extensions.
8
20 Discovering servers and synchronizing with MSSC console