Setup Guide

Table Of Contents
Error accessing console extension after updating
SCVMM R2
SCVMM displays an error for security reasons when OMIMSSC is installed and you apply an Update Rollup for SC2012 R2 VMM.
As a result you cannot access OMIMSSC.
As a workaround, do the following:
1. Delete the folder at default path: C:\Program Files\Microsoft System Center 2012 R2\Virtual Machine
Manager\Bin\AddInPipeline\AddIns\<username>.
2. Close and then open SCVMM.
3. Uninstall and then import the console extension as mentioned in Importing OMIMSSC console extension for SCVMM.
Error message while accessing OMIMSSC admin
portal through Mozilla Firefox browser
When accessing the OMIMSSC admin portal by using Mozilla Firefox browser, you get the following warning message: Secure
Connection Failed.
As a workaround, delete the certificate created from a previous entry of the admin portal in the browser.
Failure to connect to OMIMSSC Appliance
After installing OMIMSSC console extension for SCVMM in SCVMM environment, on clicking the OMIMSSC console extension
icon the following error is displayed: Connection to server failed.
As a workaround, do the following:
Add the Appliance IP and FQDN as a trusted site.
Add the Appliance IP and FQDN in Forward Lookup Zones and Reverse Lookup Zones in DNS.
Check if there are any error messages in C:\ProgramData\VMMLogs\AdminConsole file.
IP address not assigned to Appliance
After creating and starting the Appliance, the IP address is not assigned or displayed on the black console.
As a workaround, check if the virtual switch is mapped to a physical switch, configured correctly, and then connect to
Appliance.
No required permission to access SCVMM
If the SCVMM account that is used to open the SCVMM console does not meet the prerequisites, you get the following error:
You should be an Administrator/Delegated Administrator to launch the Add-In.
For information on the privileges required for SCVMM account and IG account, see Account privileges.
SCVMM error 21119 while adding servers to active
directory
While adding servers to Active Directory, SCVMM error 21119 is displayed. Error 21119: The physical computer
with <SMBIOS GUID> did not join Active Directory in time. The comptuer was expected to join
Active Directory using the computer name <host.domain>.
As a workaround, do the following:
Troubleshooting
27