Setup Guide

Table Of Contents
If you are upgrading from SC2012 VMM SP1 to SC2012 VMM R2, then upgrade to Windows PowerShell 4.0.
System requirements specific for SC2012 VMM SP1 Console:
NOTE: If you are updating to SC2012 VMM SP1, then consider the following: When importing an add-in to SC2012
VMM UR5 or later, the console may crash. For information about the issue and resolving the issue, see issue 5 in
the knowledge base URL: Support.microsoft.com/kb/2785682. Do this update irrespective of the version of the
update rollup that is installed.
Network requirements
Ports used in Appliance:
The following is a list of ports that are used by various OMIMSSC components: hence, include these ports in the firewall
exception list.
Table 4. Ports information
Usage Protocol Port Number Configurable
iDRAC communication
WSMan 443 No
FTP command client
FTP 21 No
DNS client
DNS 53 No
Dell Online Data Access
HTTP 80 No
Administration Console
HTTP 80 No
HTTPS server
HTTPS 443 No
PostgreSQL
Postgres 5432 No
Integration Gateway
HTTPS 8455 Yes. Configurable during
the Integration Gateway
installation
Autodiscovery
HTTPS 4433 No
iDRACThese ports are
enabled for iDRAC to access
the CIFS share created by the
Integration Gateway.
HTTPS 135 through to 139, and 445 No
12 System requirements for OMIMSSC