Users Guide

Table Of Contents
OMIVV Host Health
OMIVV Host Information
You can drag and drop the two portlets to the position you want and can format and customize the two portlets like other
portlets as per your requirement. To view the host summary details:
1. In the OpenManage Integration for VMware vCenter, in the Navigator pane, click Hosts.
2. In the Objects tab, select the specific host that you want to review.
3. Click the Summary tab.
4. View the host summary details:
Table 13. Host summary information
Information Description
Alternating system Displays alerts for OpenManage Integration for VMware
vCenter in a yellow box under the status area and preceding
the portlets.
Notification area Displays the Dell products integration information in the
right side-panel area, where you can find information about:
Recent Tasks
Work In Progress
Alarms
The Dell alarm information is displayed in the notification
area portlet.
5. Scroll down to view the OMIVV Server Management portlet.
Table 14. OMIVV server Management portlet (continued)
Information Description
Service Tag Displays the service tag for your PowerEdge server. Use this
ID when you call for support.
Model Name Displays the servers model name.
Fault Resilient Memory Displays the status of a BIOS attribute. The BIOS attribute
is enabled in the BIOS during initial setup of the server and
displays the memory operational mode of the server. Restart
your system when you change the memory operational mode
value. This is applicable for 12th Gen of the PowerEdge
servers and later that support Fault Resilient Memory (FRM)
option, running ESXi 5.5 or later version. The four different
values of BIOS attribute are:
Enabled and Protected: This value indicates that the
system is supported and the operating system version
is ESXi 5.5 or later and the memory operational mode in
BIOS is set to FRM.
NUMA Enabled and Protected: This value indicates that
the system is supported and the operating system
version is ESXi 5.5 or later and the memory operational
mode in BIOS is set to NUMA.
Enabled and Not Protected: This value indicates that
it supports the system with operating system version
lesser than ESXi 5.5.
Disabled: This value indicates that it supports valid
systems with any operating system version and the
memory operational mode in BIOS is not set to FRM.
Blank: If memory operational mode in BIOS is not
supported, the FRM attribute is not displayed.
System Lockdown Mode
Displays the status of the iDRAC Lockdown Mode for 14th
Gen PowerEdge servers. A closed lock represents the iDRAC
62 Inventory and warranty management