Users Guide

Table Of Contents
Host still displayed under chassis even after removing host from
vCenter tree
The hosts under the chassis are identified as part of the chassis inventory. After a successful chassis inventory, the host list
under the chassis is updated. Therefore, even if the host is removed from the vCenter tree, the host is displayed under the
chassis until the next chassis inventory is run.
In Administration Console, Update Repository Path is not set to
default path after I reset appliance to factory settings
After you reset the appliance, go to the Administration Console, and then click APPLIANCE MANAGEMENT in the left pane.
In the Appliance Settings page, the Update Repository Path is not changed to the default path.
Resolution: In Administration Console, manually copy the path in the Default Update Repository field to the Update
Repository Path field.
After backup and restore of OMIVV, alarm settings are not
restored
Restoring the OMIVV appliance backup does not restore all the Alarm settings. However, in the OpenManage Integration for
VMware GUI, the Alarms and Events field displays the restored settings.
Resolution: In the OpenManage Integration for VMware GUI, in the Manage > Settings tab, manually change theEvents and
Alarms settings.
Hypervisor deployment fails when NPAR is enabled on a target
node and disabled in System Profile
Hypervisor deployment fails when a System Profile with a disabled NIC Partitioning (NPAR) is applied on a target machine.
Here, NPAR is enabled on the target node and only one of the partitioned NIC, except partition 1 is selected as the NIC for the
Management Tasks during the deployment process through the deployment wizard.
Resolution: If you are changing the NPAR status through System Profile during deployment, ensure that you select only the first
partition for management network in the deployment wizard.
Version Affected: 4.1
Available virtual appliance version displays wrong information when
the available version is lesser than the current version
In the OMIVV Admin console, under Appliance Management, Available Virtual Appliance Version displays the modes RPM
and OVF as available.
NOTE:
It is recommended that update repository path is set to the latest version and downgrading the virtual appliance
version is not supported.
The 267027 exception is thrown while adding a 12G bare-metal
server with an Express license
During bare-metal discovery, if an incorrect credential is entered, the user account is automatically locked for few minutes.
During this period, iDRAC becomes unresponsive and takes a few minutes before restoring normalcy.
Resolution: Wait for few minutes and retype the user credentials.
Frequently Asked Questions-FAQ
155