Why is DNS configuration settings restored to original settings
after appliance reboot if appliance IP and DNS settings are
overwritten with DHCP values
There is a known defect where statically assigned DNS settings are replaced by values from DHCP. This can happen when
DHCP is used to obtain IP settings, and DNS values are assigned statically. When the DHCP lease is renewed or the appliance is
restarted, the statically assigned DNS settings are removed.
Resolution: Statically assign IP settings when the DNS server settings are different from DHCP.
Version Affected: All
Using OMIVV to update the Intel network card with firmware
version of 13.5.2 is not supported
There is a known issue with the Dell PowerEdge 12th generation servers and some Intel network cards with the firmware version
of 13.5.2. Updating some models of Intel network cards at this version of firmware fails when the firmware update is applied
by using the Lifecycle Controller. Customers with this version of firmware must update the network driver software by using
an operating system. If the Intel network card has a version of firmware other than 13.5.2, you can update using OMIVV. For
more information, see http://en.community.dell.com/techcenter/b/techcenter/archive/2013/03/20/intel-network-controller-
card-with-v13-5-2-firmware-cannot-be-upgraded-using-lifecycle-controller-to-v13-5-6.aspx
NOTE: Note: When using one-to-many firmware update, avoid selecting Intel network adapters that are at version 13.5.2,
as the update fails and stops the update task from updating remaining servers.
Using OMIVV to update Intel network card from 14.5 or 15.0 to 16.x
fails due to staging requirement from DUP
This is a known issue with NIC 14.5 and 15.0. Ensure that you use the custom catalog to update the firmware to 15.5.0 before
updating the firmware to 16.x.
Version Affected: All
Why trying firmware update with invalid DUP, hardware update job
status on vCenter console neither fails nor times-out for hours,
although job status in LC prompts as FAILED
When the invalid DUP is picked for firmware update, the status of the task in the vCenter console window remains In Progress
but the message is changed to the reason of failure. This is a known VMware defect and will be fixed in the future releases of
VMware vCenter.
Resolution: The task must be canceled manually.
Version Affected: All
Why does Administration Portal display unreachable update
repository location
If you provide an unreachable Update Repository path, the Failed: Error while connecting to the URL. error message is
displayed on the top of the Appliance Update view. However, the Update Repository Path is not cleared to the value before
update.
Resolution: Move out of this page to another page and ensure that the page is refreshed.