Description: When you create connection profile for hosts and run an inventory for the hosts, verify the physical disk and
virtual disk information at the data center, cluster, and host level. On verification, the host level inventory displays valid data
whereas in some situations, at the data center and cluster level, invalid data is displayed along with the valid set of data.
Version affected: 3.0 and later
Resolution/Workaround: This issue is infrequent, and you can press the Refresh option in the same screen to display valid
data.
● Issue 12: Hard disk option is not disabled in the Deployment wizard for all the servers that do not contain hard disk drives.
Description: While navigating through the Deployment wizard, if the bare-metal servers do not have any hard disk drive, then
the hard disk option should be disabled on the Global Settings tab. However, the option is available for selection.
Version affected: 2.0 and later
Resolution/Workaround: None
● Issue 13: The Initial Configuration wizard is displayed continuously.
Description: The Initial Configuration wizard may be displayed if you click Cancel after selecting the Do not show again
option. To properly read the Do not show again option, the wizard should move to the next page.
Version affected: 2.0 and later
Resolution/Workaround: Select the Do not show again option, and then click Next to move to the next page. Click Cancel
to close the dialog box.
● Issue 14: While applying RAID from reference server, the physical disk order is not maintained as it is in the reference server.
Description: After deploying Hardware Profile, the Virtual Disks are created on the physical server. However, the RAID levels
are applied to the same order of the physical disks as in the reference server.
Version affected: All
Resolution/Workaround: None
● Issue 15: Using OpenManage Integration to update an Intel Network card with the firmware version of 13.5.2 is not
supported.
Description: There is a known issue with Dell PowerEdge 12th generation servers and some Intel Network cards with the
firmware version of 13.5.2. Updating some models of the Intel network cards at this version of firmware fails when the
firmware update is applied using the Lifecycle Controller.
Version affected: All
Resolution/Workaround: Customers with this version of firmware must update the network driver software using an
operating system. If the Intel Network card has a version of firmware other than 13.5.2, you can update using OpenManage
Integration.
NOTE:
When using the one-to-many firmware update, avoid selecting Intel network adapters that are at version 13.5.2, as this
fails and stops the update task from updating remaining servers.
● Issue 16: Firmware upgrade or downgrade of Broadcom NetXtreme II 10 Gigabit Ethernet adapter (BCM57712) from
firmware version of 6.2.x or earlier is not supported.
Description: Using the OpenManage Integration to upgrade a Broadcom NetXtreme II 10Gigabit Ethernet adapter
(BCM57712) from firmware version of 6.2.x or earlier, or downgrade to a firmware version of 6.2.x or earlier is not
supported.
Version affected: All
Resolution/Workaround: There is a known issue with the Broadcom NetXtreme II 10Gigabit Ethernet adapter (BCM57712)
where updating the adapter from firmware version of 6.2.x or earlier, or downgrade to a firmware version of 6.2.x or
earlier fails when the update is applied using the Lifecycle Controller. When attempting to perform this update using the
OpenManage Integration, the update may incorrectly show that it completed successfully. However, the firmware update
has failed and remains at the previous level. One way to successfully update the adapter software for the Broadcom
NetXtreme II 10Gigabit Ethernet adapter (BCM57712) is for customers to update the adapter firmware from an operating
system.
● Issue 17: Running firmware update may display an error message, The firmware repository file does not exist or is invalid.
Description: While running the Firmware Update wizard, at the data center or cluster level, an error message may be
displayed: The firmware repository file does not exist or is invalid. This may be due to a daily background process that was
5