Users Guide

Table Of Contents
Table 6. Proactive HA events (continued)
Event name Description Severity
Memory spare redundancy
lost
Memory spare redundancy is lost. Check memory
device at location <location>.
Critical
Parity memory errors Parity memory errors detected on a memory device
at location <location>
Critical
Stuck bit memory error Stuck bit memory error detected on a memory
device at location <location>
Critical
Memory device disabled Memory device at location <location> is disabled Critical
Memory device
overheating
Memory device at location <location> is overheating Critical
Memory redundancy lost Memory redundancy is lost Critical
Memory mirror redundant Memory mirror is redundant Information
Memory spare redundant Memory spare is redundant Information
Self-heal operation
successfully completed
The self-heal operation successfully completed on
the memory module
Information
Memory device in a power
active state
Memory device at location <location> is in a power
active state
Information
Memory device in a power
save state
Memory device at location <location> is in a power
save state
Information
Memory device in a full
state
Memory device at location <location> is in a full
state
Information
Correctable memory
errors
Correctable memory errors detected for <location>. Warning
Memory device throttled Memory device at location <location> is throttled Warning
Degradation in the DIMM The memory health monitor feature has detected
a degradation in the DIMM installed in <location>.
Reboot system to initiate self-heal process.
Warning
Unable to complete the
self-heal process
Unable to complete the self-heal process of the
memory in the DIMM installed in <location> because
of internal issues.
Warning
Chassis events
Fan Information Fan information Info
Fan Warning Fan warning Warning
Fan Failure Fan failure Critical
Power Supply Normal The power supply returns to normal Info
Power Supply Warning The power supply detects a warning Warning
Power Supply Failure The power supply detects a failure Critical
Redundancy Information Redundancy information Info
Redundancy Degraded Redundancy is degraded Warning
Redundancy Lost Redundancy is lost Critical