Table 5. Dell Proactive HA events (continued)
Dell Inc provider event Component type Description
DellPowerRedundancy Power supply (PSU) Power redundancy event
DellIDSDMRedundancy Storage IDSDM redundancy event
NOTE: When the hosts are added to Proactive
HA enabled cluster and if IDSDM components are
present, ensure that Internal SD Card Redundancy
is configured in the iDRAC settings as Mirror.
DellMemoryRedundancy Memory Memory redundancy event
NOTE: The memory component is applicable
only for iDRAC9-based servers with the Memory
Operating Mode BIOS configurations of Advanced
ECC Mode, Mirror Mode, Spare Mode, Spare with
Advanced ECC Mode, and Dell Fault Resilient Mode.
For a Proactive HA enabled host, the following Traps are used by OMIVV as a trigger to determine the redundant health of
components:
Table 6. Proactive HA events
Event name Description Severity
Fan Information Fan information Info
Fan Warning Fan warning Warning
Fan Failure Fan failure Critical
Power Supply Normal The power supply returns to normal Info
Power Supply Warning The power supply detects a warning Warning
Power Supply Failure The power supply detects a failure Critical
Power Supply Absent The power supply is absent Critical
Redundancy Information Redundancy information Info
Redundancy Degraded Redundancy is degraded Warning
Redundancy Lost Redundancy is lost Critical
Integrated Dual SD
Module Information
Integrated Dual SD Module (IDSDM) information Info
Integrated Dual SD
Module Warning
Integrated Dual SD Module warning Warning
Integrated Dual SD
Module Failure
Integrated Dual SD Module failure Critical
Integrated Dual SD
Module Absent
Integrated Dual SD Module is absent Critical
Integrated Dual SD
Module Redundancy
Information
Integrated Dual SD Module redundancy information Info
Integrated Dual SD
Module Redundancy
Degraded
Integrated Dual SD Module redundancy is degraded Warning
Integrated Dual SD
Module Redundancy Lost
Integrated Dual SD Module redundancy is lost Critical
Memory mirror
redundancy lost
Memory mirror redundancy is lost. Check memory
device at location(s) <location>.
Critical
Manage OMIVV appliance settings 93