Users Guide

Table Of Contents
Non-compliant 11G PowerEdge servers are retained in OMIVV
inventory after backup and restore
After performing the backup and restore operation in OMIVV, the non-compliant and non-inventoried 11G hosts are still
associated to the Host Credential Profile. However, if you try to fix the configuration compliance and run a fresh inventory,
the job fails on the unsupported 11G servers.
Resolution: 11G servers are not supported with OMIVV 5.0. Manually remove the unsupported 11G hosts from the host credential
profile.
Version Affected: 5.0
Sometimes post RPM upgrade of OMIVV appliance, multiple
entries in the logs are seen in vCenter Recent Tasks
Sometimes, after RPM upgrade, multiple entries are displayed in logs when viewed on vCenter Recent Tasks.
Resolution: Restart the vCenter services.
Version Affected: 4.3
Dell EMC icon is not displayed after backup and restore from an
earlier OMIVV version to a later OMIVV version
After backup and restore from an earlier OMIVV version to a later OMIVV version, the following issues are observed:
The Dell EMC logo is not displayed at vCenter.
The 2000000 error
The 3001 error
Resolution:
Restart vSphere Client on the vCenter server.
If the issue persists:
For VMware vCenter Server Appliance, go to /etc/vmware/vsphere-ui/vc-packages/vsphere-client-
serenity and for Windows vCenter, go to C:\ProgramData\VMware\vCenterServer\cfg\vsphere-
ui\vc-packages\vsphere-client-serenity folder in the vCenter appliance and see if the old data exists,
such as: com.dell.plugin.OpenManage_Integration_for_VMware_vCenter_WebClient-X.0.0.XXX.
Manually delete the folder corresponding to the earlier OMIVV version.
OMIVV RPM upgrade fails when proxy is configured with domain
user authentication
If OMIVV appliance is configured with proxy to reach the Internet and proxy is authenticated using NTLM authentication, then
the RPM update fails due to the issues in the underlying yum tool.
Version Affected: OMIVV 4.0 and above
Resolution / Work around: Do Back up and Restore to update the OMIVV appliance.
After backup and restore of OMIVV, alarm settings are not
restored
Restoring the OMIVV appliance backup does not restore all the Alarm settings. However, in the OpenManage Integration for
VMware GUI, the Alarms and Events field displays the restored settings.
Resolution: In the OMIVV GUI, in the Settings tab, manually change the Events and Alarms settings.
166