Some controllers do not allow creation of a RAID 0 array with one drive. This feature is supported only on high-end
controllers, and the application of such a hardware profile can cause failures.
Enabling auto discovery on newly purchased system
About this task
The auto discovery feature of a host system is not enabled by default; instead, enablement must be requested at the time
of purchase. If auto discovery enablement is requested at the time of purchase, DHCP is enabled on the iDRAC and admin
accounts are disabled. It is not necessary to configure a static IP address for the iDRAC. It gets one from a DHCP server on
the network. To use the auto discovery feature, a DHCP server or a DNS server (or both) must be configured to support the
discovery process. CSIOR should already be run during the factory process.
If auto discovery was not requested at the time of purchase, it can be enabled as follows:
Steps
1. During the boot routine, press Ctrl+E.
2. In the iDRAC setup window, enable the NIC (blade servers only).
3. Enable Auto-Discovery.
4. Enable DHCP.
5. Disable admin accounts.
6. Enable Get DNS server address from DHCP.
7. Enable Get DNS domain name from DHCP.
8. In the Provisioning Server field, enter:
<OpenManage Integration virtual appliance IPaddress>:4433
Firmware update
Running firmware update may display an error message, The
firmware repository file does not exist or is invalid.
While running the Firmware Update wizard, at cluster level, an error message may be displayed: The firmware repository
file does not exist or is invalid. This may be due to a daily background process that was unable to download and cache the
catalog file from the repository. This occurs if the catalog file is not reachable at the time the background process runs.
Resolution: After resolving any catalog connectivity issues that may exist, you can reinitiate the background process by
changing the firmware repository location, and then setting it back to the original location. Allow about five minutes for the
background process to complete. Ensure that there is no @ character present in the credential that is provided for the CIFS.
Also, ensure that the DUP file exists in the share location.
Version Affected: All
Why did system not enter maintenance mode when I performed
one-to-many firmware update
Some firmware updates do not require rebooting the host. In that case, the firmware update is performed without putting the
host into maintenance mode.
What should I do as firmware update failed
Check the OMIVV appliance logs to see if the tasks timed out. If so, iDRAC must be reset by performing a cold reboot. After the
system is up and running, check to see if the update was successful by either running an inventory or by using the Firmware
tab.
Frequently Asked Questions-FAQ
163