Deployment job times out when network interface card (NIC) of
OMIVV is not connected to the ESXi host network
OS deployment has dependency on the selection of NIC. If the correct NIC is not selected, then OSD job times out.
Resolution: Select appropriate 'Appliance NIC connected to Host ' from Configure Host Settings page of Deployment wizard .
This is needed by OMIVV to reach ESXi network during OS installation process.
Deployment job fails in OMIVV
The deployment job fails because LifeCycle Controller is busy in completing pending or running other jobs.
Resolution: Perform the following:
1. Clear iDRAC job queue in iDRAC [Optional]
2. Reset iDRAC
3. Run the deployment job again
Version affected: All
Unable to apply System Profile that has PCIe card in the FX chassis
The OS deployment fails on a target server if the source server has PCIe card information when using an FX chassis. The
System profiles on the source server have different fc.chassislot ID than the one on the target server. OMIVV tries to
deploy the same fc.chassislot ID on the target server but fails. The System profiles searches for exact instance( FQDD)
while applying the profile, which works successfully on rack servers (identical), but may have few restrictions in modular
servers. For example, in FC640, the System profiles that are created from one modular server cannot be applied on other
modular servers in the same FX chassis because of NIC level restrictions.
Version Affected: 4.1 and later.
Resolution: System profile that is taken from an FC640 server in slot 1 of a FX2s chassis can only be applied on another FC640
server residing in the slot 1 of another FX2s chassis.
NFS share is set up with ESXi ISO, but deployment fails with errors
mounting share location
About this task
To find the solution:
Steps
1. Ensure that the iDRAC can ping the appliance.
2. Ensure that your network is not running too slow.
3. Ensure that the ports: 2049, 40014004 are open and the firewall is set accordingly.
Bare-metal deployment issues
This section deals with issues found during the deployment process.
Auto discovery and handshake prerequisites
Prior to running auto discovery and handshake, ensure that iDRAC and Lifecycle Controller firmware and BIOS versions meet
the minimum recommendations.
CSIOR must have run at least once on the system or iDRAC.
Hardware configuration failure
Before initiating a deployment task, ensure that the system has completed CSIOR and is not in the process of rebooting.
BIOS configuration should be run in clone mode so that the reference server is an identical system.
162