Users Guide

Table Of Contents
Table 9. Virtualization events (continued)
Event name Description Severity Recommended action
Dell-Fan sensor detected a nonrecoverable
value
A fan sensor
detected an error
from which it cannot
recover
Error No action
Dell-Voltage sensor returned to a normal
value
Sensor Returned to
Normal Value
Info No action
Dell-Voltage sensor detected a warning
value
A voltage sensor
in the specified
system exceeded its
warning threshold
Warning No action
Dell-Voltage sensor detected a failure value A voltage sensor in
the specified system
exceeded its failure
threshold
Error Put the system into maintenance mode
Dell-Voltage sensor detected a
nonrecoverable value
A voltage sensor in
the specified system
detected an error
from which it cannot
recover
Error No action
Dell-Current sensor returned to a normal
value
Sensor Returned to
Normal Value
Info No action
Dell-Storage: storage management error Storage
management has
detected a device
independent error
condition
Error Put the system into maintenance mode
Dell-Storage: Controller warning A portion of the
physical disk is
damaged
Warning No action
Dell-Storage: Controller failure A portion of the
physical disk is
damaged
Error Put the system into maintenance mode
Dell-Storage: Channel Failure Channel failure Error Put the system into maintenance mode
Dell-Storage: Enclosure hardware
information
Enclosure hardware
information
Info No action
Dell-Storage: Enclosure hardware warning Enclosure hardware
warning
Warning No action
Dell-Storage: Enclosure hardware failure Enclosure hardware
error
Error Put the system into maintenance mode
Dell-Storage: Array disk failure Array disk failure Error Put the system into maintenance mode
Dell-Storage: EMM failure EMM failure Error Put the system into maintenance mode
Dell-Storage: power supply failure Power supply failure Error Put the system into maintenance mode
Dell-Storage: temperature probe warning Physical disk
temperature probe
warning, too cold or
too hot
Warning No action
Dell-Storage: temperature probe failure Physical disk
temperature probe
error, too cold or too
hot.
Error Put the system into maintenance mode