Users Guide

Table Of Contents
Table 9. Virtualization events (continued)
Event name Description Severity Recommended action
event. If a
temperature sensor
reading exceeds the
error threshold for
which the system
is configured, the
operating system
shuts down and
the system powers
off. This event
may also be
initiated on certain
systems when a
fan enclosure is
removed from the
system for an
extended period of
time
Dell-Temperature sensor returned to a
normal value
Sensor Returned to
Normal Value
Info No action
Dell-Temperature sensor detected a
warning value
A temperature
sensor on the
backplane board,
system board, CPU,
or drive carrier
in the specified
system exceeded its
warning threshold
Warning No action
Dell-Temperature sensor detected a failure
value
A temperature
sensor on the
backplane board,
system board, or
drive carrier in the
specified system
exceeded its failure
threshold value
Error Put the system into maintenance mode
Dell-Temperature sensor detected a non-
recoverable value
A temperature
sensor on the
backplane board,
system board, or
drive carrier in the
specified system
detected an error
from which it cannot
recover
Error No action
Dell-Fan sensor returned to a normal value Sensor Returned to
Normal Value
Info No action
Dell-Fan sensor detected a warning value Fan Sensor reading
in the host <x>
exceeded a warning
threshold value
Warning No Action
Dell-Fan sensor detected a failure value A fan sensor in
the specified system
detected the failure
of one or more fans
Error Put the system into maintenance mode
Manage vCenter settings 109