Users Guide

Table Of Contents
Table 9. Virtualization events (continued)
Event name Description Severity Recommended action
Dell-alertLiquidCoolingLeakFailure A large leak is
detected on the
device
Critical Disconnect the input power, and then
immediately contact your service provider.
Dell-
alertStorageSoftwareDefinedSubSystemFail
ure
Software defined
storage subsystem
failure
Critical Verify the health status of the hard drive
identified in the message and retry the
operation. To check the health status on
the iDRAC GUI, on the iDRAC dashboard,
click Storage > Physical Disks. Run the
following RACADM command at Command
Line Interface (CLI): racadm raid get
pdisks -o -p status
Add more physical drives to the storage
pool and retry the operation.
Dell-
alertStorageSoftwareDefinedSubSystemWa
rning
Software defined
storage subsystem
warning
Warning No action
Dell-alertTemperatureProbeReadWarning Unable to
read Temperature
Sensors
Warning No action
Dell-alertTemperatureProbeChangeFailure Temperature
increase Error
Critical Check the chassis event log for fan
issues and fix any issues present. If fan
issues are not detected, check chassis
ambient temperature and make sure the
temperature is within operating range. To
check the chassis ambient temperature,
run the following RACADM command:
racadm getsensorinfo.
Dell-Current sensor detected a warning
value
A current sensor
in the specified
system exceeded its
warning threshold
Warning No action
Dell-Current sensor detected a failure value A current sensor in
the specified system
exceeded its failure
threshold
Error Put the system into maintenance mode
Dell-Current sensor detected a non-
recoverable value
A current sensor in
the specified system
detected an error
from which it cannot
recover
Error No action
Dell-Redundancy regained Sensor Returned to
Normal Value
Info No action
Dell-Redundancy degraded A redundancy sensor
in the specified
system detected
that one of the
components of the
redundancy unit has
failed but the unit is
still redundant
Warning No action
Dell-Redundancy lost A redundancy sensor
in the specified
system detected
Error Put the system into maintenance mode
106 Manage vCenter settings