Users Guide

Table Of Contents
Table 9. Virtualization events
Event name Description Severity Recommended action
The power supplies are
redundant
None Info No action
The power supplies are not
redundant
The current power supply
configuration does not meet
the platform requirements to
enable redundancy. If a power
supply fails the system may
shut down.
Info If unintended, review system
configuration and power
consumption and install power
supplies accordingly. Check
power supply status for
failures
The power supplies are
not redundant. Insufficient
resources to maintain normal
operations
The system may power down
or operate in a performance
degraded state
Critical Check the event log for
power supply failures. Review
system configuration and
power consumption and
upgrade or install power
supplies accordingly
Fan redundancy is lost One of more fans have
failed or have been removed
or a configuration change
occurred, which requires
additional fans
Critical Remove and reinstall failed
fans or install additional fans
Fan redundancy is degraded One of more fans have
failed or have been removed
or a configuration change
occurred, which requires
additional fans.
Warning Remove and reinstall failed
fans or install additional fans
The fans are redundant None Info No action
The fans are not redundant One of more fans have
failed or have been removed
or a configuration change
occurred, which requires
additional fans
Info Remove and reinstall failed
fans or install additional fans
The fans are not redundant.
Insufficient resources to
maintain normal operations
One of more fans have
failed or have been removed
or a configuration change
occurred, which requires
additional fans
Critical Remove and reinstall failed
fans or install additional fans
Managing data retrieval schedule
Schedule inventory job
To view the latest inventory data on OMIVV, you must schedule an inventory job to run periodically to ensure that inventory
information of hosts or the chassis is up-to-date. It is recommended that you run the inventory job on a weekly- basis.
NOTE:
The chassis is managed in OMIVV context. There is no context of vCenter in chassis management. After scheduled
host inventory is complete, the chassis inventory is triggered for all the chassis that are managed using OMIVV.
NOTE: The settings in this page are reset to default each time the configuration wizard is invoked. If you have previously
configured a schedule for inventory, ensure that you replicate the previous schedule in this page before completing the
wizard functions so that the previous schedule is not overridden by the default settings.
1. On the OMIVV home page, click Settings > vCenter Settings > Data Retrieval Schedule > Inventory Retrieval.
2. Select the Enable Inventory Data Retrieval (Recommended) check box.
Manage vCenter settings