Table 9. Virtualization events (continued)
Event name Description Severity Recommended action
Dell-Power Supply audit
failure or critical event
Power supply audit failure or
critical event
Error Put the system into
maintenance mode
Dell-Power usage audit
warning
Power usage audit warning Warning No action
Dell-Power usage audit failure
or critical event
Power usage audit failure or
critical event
Error Put the system into
maintenance mode
Dell-Security configuration
warning
Security configuration
warning
Warning No action
Dell-Configuration: Software
configuration warning
Configuration: Software
configuration warning
Warning No action
Dell-Configuration: Software
configuration failure
Configuration: Software
configuration failure
Error Put the system into
maintenance mode
Dell-Virtual Disk Partition
failure
Virtual disk partition failure Error Put the system into
maintenance mode
Dell-Virtual Disk Partition
warning
Virtual disk partition warning Warning No action
iDRAC events
NOTE: For all Proactive HA enabled hosts that are part of a cluster, the following virtualization events are mapped to the
Proactive HA events; except events, "The fans are not redundant" and "The power supplies are not redundant" are not
mapped.
The fans are redundant None Info No action
Fan redundancy is lost One of more fans have
failed or have been removed
or a configuration change
occurred, which requires
additional fans
Critical Remove and reinstall failed
fans or install additional fans
Fan redundancy is degraded One of more fans have
failed or have been removed
or a configuration change
occurred, which requires
additional fans.
Warning Remove and reinstall failed
fans or install additional fans
The fans are not redundant One of more fans have
failed or have been removed
or a configuration change
occurred, which requires
additional fans
Info Remove and reinstall failed
fans or install additional fans
The fans are not redundant.
Insufficient resources to
maintain normal operations
One of more fans have
failed or have been removed
or a configuration change
occurred, which requires
additional fans
Critical Remove and reinstall failed
fans or install additional fans
The power supplies are
redundant
None Info No action
Power supply redundancy is
lost
The current power
operational mode is non-
redundant because of a
power supply exception,
a power supply inventory
change, or a system power
inventory change. The system
Critical Check the event log for
power supply failures. Review
system configuration and
power consumption
Manage vCenter settings 91