Users Guide

Table Of Contents
View alarms and events setting
After you configure alarms and events, you can view if the vCenter alarms for hosts are enabled and which event posting level is
selected on the Settings tab.
1. On the OMIVV home page, click Settings > Events and Alarms.
The following details are displayed:
vCenter alarms for Dell EMC hostsDisplays either Enabled or Disabled.
Event posting level
2. Configure events and alarms. See Configure events and alarms on page 85.
To view the event posting levels, see About events and alarms on page 84.
Virtualization-related events
The following table contains the virtualization-related critical and warning events, and includes event name, description, severity
level, and recommended action.
The vitalization-related events are displayed in the following format:
Dell-Message ID:<ID number>, Message:<Message Description>.
The chassis events are displayed in the following format:
Dell-Message:<Message description>, Chassis name:<name of the chassis>, Chassis Service Tag:<chassis Service Tag >,
Chassis Location:<chassis location>
Table 9. Virtualization events
Event name Description Severity Recommended action
Dell-Current sensor detected
a warning value
A current sensor in the
specified system exceeded its
warning threshold
Warning No action
Dell-Current sensor detected
a failure value
A current sensor in the
specified system exceeded its
failure threshold
Error Put the system into
maintenance mode
Dell-Current sensor detected
a non-recoverable value
A current sensor in the
specified system detected an
error from which it cannot
recover
Error No action
Dell-Redundancy regained Sensor Returned to Normal
Value
Info No action
Dell-Redundancy degraded A redundancy sensor in the
specified system detected
that one of the components
of the redundancy unit has
failed but the unit is still
redundant
Warning No action
Dell-Redundancy lost A redundancy sensor in the
specified system detected
that one of the components
in the redundant unit has
been disconnected, has failed,
or is not present
Error Put the system into
maintenance mode
Dell-Power supply returned to
normal
Sensor returned to Normal
Value
Info No action
Dell-Power supply detected a
warning
A power supply sensor
reading in the specified
system exceeded a user
definable warning threshold
Warning No action
86 Manage vCenter settings