Deploy ISO profile (ESXi installation)
You can perform the deployment only on the compliant bare-metal servers. For more information, see View bare-metal servers
on page 49.
1. On the System Profile and ISO Profile Deployment Checklist page of the deployment wizard, verify the deployment
checklist, and then click GET STARTED.
2. On the Select Server (s) page, select one or more servers.
The Select Deployment Options page is displayed.
3. On the Select Deployment Options page, select ISO Profile (ESXi installation).
4. From the vCenter Name drop-down menu, select an instance of vCenter.
5. To select the vCenter destination container, click BROWSE, and select an appropriate data center or cluster on which you
want to deploy an operating system.
6. From the ISO Profile drop-down menu, select an appropriate ISO profile.
7. Under Installation Target, select any one of the following:
First boot diskdeploys an operating system on the Hard Drive, Solid State Drive (SSD), or virtual drive created by
RAID controllers.
Internal Dual SD Module (IDSDM)deploys an operating system on the IDSDM. If an IDSDM is available on at least
one of the selected servers, the Internal Dual SD Module option is enabled. If not, only the First boot Disk option is
available.
If any one of the selected servers does not support an IDSDM or BOSS module, or if an IDSDM or BOSS is not
installed in the servers during deployment then the deployment operation on those servers is skipped. To deploy an
operating system on the first boot disk of the servers, select the Deploy the hypervisor to the first boot disk for
servers that do not have an available Internal Dual SD Module check box.
NOTE:
The First boot disk installation target is not equivalent to the first entry in the BIOS Hard Drive Sequence
or UEFI Boot sequence. This option deploys an operating system on to the first disk identified by the ESXi pre-OS
environment. Therefore, ensure that the Hard-Disk FailOver or Boot sequence retry option is enabled when the First
Boot Disk option is selected.
BOSSdeploys an operating system on the BOSS card. If BOSS is available on at least one of the selected servers, the
BOSS option is enabled. If not, only the First boot Disk option is available.
If you are using OMIVV to deploy an operating system on the BOSS controller, ensure that system profile is captured
from the reference server along with the BOSS VD configuration and target server must have a BOSS with similar
configuration. For more information about creating VD, see Dell EMC Boot Optimized Server Storage-S1 User's Guide at
www.dell.com/support.
8. On the Select Host Credential Profile page, perform the following tasks:
a. To use the same host credential profile for all hosts, click YES, and then select the host credential profile from the
drop-down menu.
b. To select the individual host credential profile for each server, click NO, and then select the host credential profile from
the drop-down menu.
NOTE:
If AD credentials are used for iDRAC or ESXi in host credential profile, those profiles are not considered for an
operating system deployment.
NOTE: In host credential profile, it is recommended that you associate the user that is used to discover the bare-metal,
else the discovered user gets disabled in iDRAC after operating system deployment.
9. On the Configure Network Settings page, perform the following tasks:
a. Enter a Fully Qualified Host Name (FQDN) for the server. A fully qualified domain name for the hostname is mandatory.
The use of localhost for the FQDN is not supported. The FQDN is used when adding the host to vCenter. Create a DNS
record that resolves the IP address with the FQDN. Configure the DNS server to support reverse lookup requests. The
DHCP reservations and DNS host names must be in place and verified before the deployment job is scheduled to run.
NOTE:
If vCenter is registered with OMIVV using FQDN, ensure that the ESXi host could resolve the FQDN using
DNS resolution .
b. Select the NIC that is used for management network. Ensure that NIC is in connected state.
NOTE:
Ensure that you select the management NICs based on the network connectivity to the OMIVV. The APPLY
SETTINGS TO ALL SERVERS option is not applicable for management NIC selection.
54 Deployment