Users Guide

Table Of Contents
Table 6. Virtualization-related Events of 11th, 12th, and 13th Generation PowerEdge Servers (continued)
Dell - Battery sensor detected
a nonrecoverable value
A battery sensor in the
specified system detected
that a battery has failed.
Error No Action
Dell - Thermal shutdown
protection has been initiated
This message is generated
when a system is configured
for thermal shutdown due
to an error event. If a
temperature sensor reading
exceeds the error threshold
for which the system is
configured, the operating
system shuts down and the
system powers off. This event
may also be initiated on
certain systems when a fan
enclosure is removed from the
system for an extended period
of time.
Error No action
Dell - Temperature sensor
returned to a normal value
Sensor Returned to Normal
Value.
Info No action
Dell - Temperature sensor
detected a warning value
A temperature sensor on
the backplane board, system
board, CPU, or drive
carrier in the specified
system exceeded its warning
threshold.
Warning No action
Dell - Temperature sensor
detected a failure value
A temperature sensor on
the backplane board, system
board, or drive carrier in the
specified system exceeded its
failure threshold value.
Error Put the system into
maintenance mode
Dell - Temperature sensor
detected a non-recoverable
value
A temperature sensor on
the backplane board, system
board, or drive carrier in the
specified system detected an
error from which it cannot
recover.
Error No action
Dell - Fan sensor returned to a
normal value
Sensor Returned to Normal
Value
Info No action
Dell - Fan sensor detected a
warning value
Fan Sensor reading in the
host <x> exceeded a warning
threshold value.
Warning No Action
Dell - Fan sensor detected a
failure value
A fan sensor in the specified
system detected the failure of
one or more fans.
Error Put the system into
maintenance mode
Dell - Fan sensor detected a
nonrecoverable value
A fan sensor detected an
error from which it cannot
recover.
Error No action
Dell - Voltage sensor returned
to a normal value
Sensor Returned to Normal
Value
Info No action
Dell - Voltage sensor detected
a warning value
A voltage sensor in the
specified system exceeded its
warning threshold
Warning No action
Virtualization-related Events For Dell PowerEdge Servers 129