In the Calendar box, select the month and day.
In the Time text box, type the time in HH:MM, and then click Next. The time is the local time zone where your client is
physically located. Invalid time values result in a blocked update.
Apply updates on next reboot.
To avoid a service interruption, it is recommended that the host enters maintenance mode before the reboot.
Apply updates and force reboot without entering maintenance mode.
The update is applied, and a reboot occurs even if the host is not in maintenance mode. This method is not
recommended.
10. Click Next. The Summary page is displayed that provides details about all components after firmware update.
11. Click Finish.
12. To verify that the update was successful, in Monitor tab, select Job Queue > Firmware Updates, and review the
OpenManage Integration Overview page to see the new versions.
Running the Update Firmware Wizard for a Cluster
This functionality is only available for 11th, 12th, and 13th generation Dell servers that have either an iDRAC Express or
Enterprise card. If your firmware was installed on or after October 14th, 2010, you can automatically update your firmware
versions using the Firmware Update Wizard. This wizard only updates hosts that are part of a connection profile and compliant
in terms of firmware, CSIOR status, hypervisor, and OMSA status (11th generation servers only). Select a cluster that is listed in
the Clusters view and use the Firmware Update Wizard. It typically takes from 30 to 60 minutes to update firmware components
for each cluster. Enable DRS on a cluster so that virtual machines can be migrated when a host enters/exits maintenance mode
during the firmware update process. You can only schedule or run one firmware update task at a time.
If you want to export from the wizard, use the Export to CSV button. Search is available for locating a specific cluster,
datacenter, host, or any topic item from the datagrid except for Date Applied.
NOTE:
VMware recommends clusters to be built with identical server hardware. For the firmware update at a cluster level
with the number of hosts near the limits for a cluster (recommended by VMware) or composed of different models of Dell
servers, usage of vSphere web client is recommended.
NOTE: For information on changing the default timeout setting, see the Troubleshooting section of the Users Guide.
You can view the status and manage Firmware update jobs from the Job Queue page. See, Viewing Firmware Details for
Datacenters and Clusters.
1. Click OpenManage Integration icon, click Clusters that is displayed in the left pane. The list of clusters are displayed.
2. Click a cluster from the displayed list. The main menu is displayed with different options.
3. Click Monitor -->Dell Cluster Information -->Firmware. The Run Firmware Wizard screen is displayed.
4. Click Run Firmware Wizard link. The Welcome page is displayed.
5. Click Next. The Select Update Source screen is displayed where you can select the bundles. The Repository location is
also displayed.
6. Select host from the displayed list in the Select Bundles area. You should select at least one bundle for firmware update.
Each host has a drop-down list next to the host name from which you can select the required bundle.
NOTE:
64-bit bundles are not supported for 12th generation hosts with iDRAC version 1.51 and earlier.
64-bit bundles are not supported for 11th generation hosts on all iDRAC versions.
7. Click Next. The Select Components screen is displayed. This screen displays the details of components such as, model
name, host name, service tag, component, and so on for the selected host.
8. Select at least one component from the list, and click Next to proceed. You can filter the content of the component data
grid using the Filter field or, drag and drop columns within the component data grid. If you select the Allow Firmware
downgrade check box, the existing firmware version rolls back to the previous available version.
9. Click Next, the Schedule Firmware Update screen is displayed.
a. Enter the firmware update job name in the Firmware Update Job Name field. This value is mandatory.
b. Enter the firmware update description in the Firmware Update Description field. This value is optional.
10. Select an option from the following.
Settings
51