Users Guide

Table Of Contents
For an ESXi host, you must install OMSA VIB using the VMware Remote CLI tool, and reboot the system.
Can the OpenManage Integration for VMware vCenter Support
ESXi with Lockdown Mode Enabled?
Yes. Lockdown Mode is supported in this release on hosts ESXi 5.0 and above.
When I tried to use lockdown mode, it failed.
When I added a host to the connection profile in lockdown mode, the inventory kicked off but failed stating that No Remote
Access Controller was found or Inventory is not supported on this host. Inventory is supposed to work for a host in lockdown
mode, right?
If you put the host in lockdown mode or remove a host from lockdown mode, you must wait 30minutes before performing the
next operation on the OpenManage Integration for VMware vCenter.
What Setting Should I Use For UserVars.CIMoeMProviderEnable
With ESXi 4.1 U1?
Set UserVars.CIMoemProviderEnabled to 1.
I Am Using A Reference Server to Create a Hardware Profile But it
Failed. What Should I Do?
Check to make sure that minimum recommended versions of iDRAC firmware, Lifecycle Controller firmware, and BIOS are
installed.
To make sure that the data retrieved from the reference server is current, enable Collect System Inventory On Restart
(CSIOR), and restart the reference server prior to extraction of data.
I Am Attempting to Deploy ESXi on a Blade Server and it Failed.
What Should I Do?
1. Make sure the ISO location (NFS path) and staging folder paths are accurate.
2. Make sure the NIC selected during assignment of server identity is on the same network as the virtual appliance.
3. If using static IP address, make sure the network information provided (including subnet mask and default gateway) is
accurate. In addition, , make sure the IPaddress is not already assigned on the network.
4. Make sure at least one Virtual Disk is seen by the system. ESXi also installs to an internal RIPS SD card.
Why are My Hypervisor Deployments Failing on my Dell PowerEdge
R210 II Machines?
A timeout issue on Dell PowerEdge R210 II systems produces a hypervisor deployment failure error due to the failure of the BIOS
to boot from the attached ISO. To resolve this issue, manually install hypervisor on the machine.
Why Do I See Auto-discovered Systems Without Model Information
in the Deployment Wizard
This usually indicates that the firmware version installed on the system does not meet recommended minimum requirements. In
some cases, a firmware update may not have registered on the system. Cold booting the system or reseating the blade fixes this
Troubleshooting