Users Guide

Table Of Contents
In the Administration Console, why the Update Repository Path
is not set to default path after I reset the appliance to factory
settings?
After you reset the appliance, go to the Administration Console, and then click APPLIANCE MANAGEMENT in the left pane. In
the Appliance Settings page, the Update Repository Path is not changed to default path.
Resolution: In the Administration Console, manually copy the path in the Default Update Repository field to Update
Repository Path field.
After backup and restore of OpenManage Integration for VMware
vCenter, why alarm settings are not restored?
Restoring the OpenManage Integration for VMware vCenter appliance backup does not restore all the Alarm settings. However,
in the OpenManage Integration for VMware GUI, the Alarms and Events field displays the restored settings.
Resolution: In the OpenManage Integration for VMware GUI, in the Manage > Settings tab, manually change the Events and
Alarms settings.
Bare Metal Deployment Issues
This section deals with issues found during the deployment process.
Auto-Discovery and Handshake Prerequisites
Prior to running auto-discovery and handshake, make sure that iDRAC and Lifecycle Controller firmware and BIOS versions
meet the minimum recommendations.
CSIOR must have run at least once on the system or iDRAC.
Hardware Configuration Failure
Before initiating a deployment task, make sure the system has completed CSIOR and is not in the process of rebooting.
It is highly recommended that BIOS configuration be run in Clone mode, so that the reference server is an identical system.
Some controllers do not allow creation of a RAID 0 array with one drive. This feature is supported only on high-end
controllers, and the application of such a hardware profile can cause failures.
Enabling Auto-Discovery On A Newly Purchased System
The auto-discovery feature of a host system is not enabled by default; instead, enablement must be requested at the time
of purchase. If auto-discovery enablement is requested at the time of purchase, DHCP is enabled on the iDRAC and admin
accounts are disabled. It is not necessary to configure a static IP address for the iDRAC. It gets one from a DHCP server on the
network. To make use of the auto-discovery feature, a DHCP server or a DNS server (or both) must be configured to support
the discovery process. CSIOR has already been run by factory process.
If auto-discovery was not requested at the time of purchase, it can be enabled as follows:
1. During the boot process, press <Ctrl + E>.
2. In the iDRAC setup window, enable the NIC (blade servers only).
3. Enable Auto-Discovery.
4. Enable DHCP.
5. Disable admin accounts.
6. Enable Get DNS server address from DHCP.
7. Enable Get DNS domain name from DHCP.
8. In the Provisioning Server field, enter:
<OpenManage Integration virtual appliance IPaddress>:4433
Troubleshooting
85