12. Select Apply Changes, and the temperature warning event is generated. To cause another event, restore the original
settings using the same Set to Values option. Events are generated as warnings, and then to a normal state. If everything is
working properly, navigate to the vCenter Tasks & Events view; a temperature probe warning event should be displayed.
NOTE: There is a filter for duplicate events; if you try to trigger the same event too many times in a row, you will only
receive one event. Allow at least 30 seconds between events to see all events.
I Have the OMSA Agent Installed on a Dell Host System, But I Still
Get an Error Message That OMSA is Not Installed. What Should I
Do?
To resolve this issue on an 11th generation server:
1. Install OMSA with the Remote Enablement component on the host system.
2. If you are using the command line to install OMSA, make sure to specify the -c option. If OMSA is already installed, reinstall
it with the -c option and restart the service:
srvadmin-install.sh -c
srvadmin-services.sh restart
For an ESXi host, you must install OMSA VIB using the VMware Remote CLI tool, and reboot the system.
Can the OpenManage Integration for VMware vCenter Support
ESXi with Lockdown Mode Enabled?
Yes. Lockdown Mode is supported in this release on hosts ESXi 5.0 and above.
When I tried to use lockdown mode, it failed.
When I added a host to the connection profile in lockdown mode, the inventory kicked off but failed stating that No Remote
Access Controller was found or Inventory is not supported on this host. Inventory is supposed to work for a host in lockdown
mode, right?
If you put the host in lockdown mode or remove a host from lockdown mode, you must wait 30minutes before performing the
next operation on the OpenManage Integration for VMware vCenter.
On trying a firmware update with an invalid DUP, the hardware
update job status on the vCenter console neither fails nor times-
out for hours, though the job status in LC says FAILED. Why is
this happening?
When the invalid DUP is picked for firmware update, the status of the task in the vCenter console window remains In Progress
but the message is changed to the reason of failure. This is a known VMware defect and will be fixed in the future releases of
VMware vCenter.
Resolution: The task has to be cancelled manually.
Version Affected: All
What Setting Should I Use For UserVars.CIMoeMProviderEnable
With ESXi 4.1 U1?
Set UserVars.CIMoemProviderEnabled to 1.