Administration Portal is still showing the unreachable Update
Repository location.
If the user provided a unreachable Update Repository path, the error message Failed: Error while connecting to the URL . is
displayed on the top of the Appliance Update view, however the Update Repository Path is not cleared out to the value before
update.
Resolution: Move out of this page to another page and make sure the page is refreshed.
Version Affected: All
Why is the DNS configuration settings restored to original settings
after appliance reboot if using DHCP for appliance IP and DNS
settings overwritten
There is a known defect where statically assigned DNS settings are replaced by values from DHCP. This can happen when
DHCP is used to obtain IP settings, and DNS values are assigned statically. When the DHCP lease is renewed or the appliance
is restarted the statically assigned DNS settings are removed. Resolution: Statically assign IP settings when the DNS server
settings will be different from DHCP.
Version Affected: All
Why did my system not enter maintenance mode when I performed
a one-to-many firmware update?
Some firmware updates do not require rebooting the host. In that case, the firmware update is performed without putting the
host into maintenance mode.
Even if my repository has bundles for selected 11G system, why
is firmware update showing that I have no bundles for Firmware
Update?
When I added a host to the connection profile in lockdown mode, the inventory kicked off but failed stating that No Remote
Access Controller was found or Inventory is not supported on this host. Inventory is supposed to work for a host in lockdown
mode, right?
If you put the host in lockdown mode or remove a host from lockdown mode, you must wait 30minutes before performing the
next operation. If you use a 11G host for firmware update, the firmware update wizard will not show any bundles even if the
repository provided has bundles for that system. This occurs because the 11G host might have not been configured for OMSA
to send traps to OpenManage Integration.
Resolution: Ensure that the host is compliant using the host Compliance screen of OpenManage Integration desktop client. If it
is not compliant, use the fix Host Compliance to get it compliant.
Version Affected: 2.2 and later
Why Does My ESXi Deployment Fail on Servers Having a PERC
S300 Boot Controller?
Deployments of OpenManage Integration for VMware vCenter using different ESXi versions on Dell PowerEdge servers with the
PERC S300 boot controller failed. The Dell customized ESXi operating systems do not carry the driver for the PERC S300 boot
controller, which causes the boot controller/HDD not to be recognized during operating system installation. Servers with PERC
S300 boot controllers are not supported for OpenManage Integration for VMware vCenter deployments.
Troubleshooting