the Welcome page and then click Next, a message is displayed mentioning that the bundles are not retrieved from firmware
repository in the Select Update Source screen.
Resolution/Workaround: You can select the desired firmware updates and click Next to continue with the firmware update.
Version Affected: 3.0 and later
Issue 8: On running a warranty retrieval job, the warranty job status is not listed in the Warranty Job Queue page.
Description: If your network needs proxy details to connect to the internet and the proxy is not set on the OMIVV appliance,
the warranty retrieval job fails and the job is not listed under warranty job queue.
Resolution/Workaround: Set the proxy details and trigger the warranty job again.
Version Affected: All
Issue 9: If vCenter is idle for few hours, the OMIVV content is replaced by a "!" icon on clicking the OpenManage Integration
tab and Management Center. What should I do to resume the session?
Description: If vCenter is idle for few hours, the OMIVV content is replaced by a "!" icon when you click the OpenManage
Integration tab of an inventoried host and Dell Management Center icon to perform any actions.
Resolution/Workaround: You can resume the session by closing the current session and logging in again.
Version Affected: 3.1, vCenter 6.0 and later
Issue 10: Storage overview returning incorrect number of physical disks for inventory.
Description: Systems with software RAID show incorrect number of physical disks on the storage overview page.
Resolution/Workaround: None. The ESXi does not support software RAID. If the system has software RAID it will show
incorrect disks.
Version Affected: All
Issue 11: System Event Logs are not showing in OpenManage Integration for VMware vCenter vSphere client when power
supply redundancy is lost.
Description: When the power redundancy is lost on PowerEdge 12th Generation modular servers, the system logs get cleared.
Resolution/Workaround: None
Version Affected: 3.0 and later
Issue 12: Memory data displays a negative value for a host after successful inventory.
Description: The Total Memory capacity displays as “0” and Memory Installable displays a negative value on the Host Memory
overview page. This issue occurs because of some issue in the iDRAC.
Resolution/Workaround: Restart the system and check if the issue is resolved. If issue is not resolved, you may have to reset
the iDRAC.
Version Affected: All
Issue 13: Chassis and server health is displayed as warning on the Chassis Summary page when server becomes critical.
Description: When a critical entry is made to SEL logs, the health of the server (blade) changes to critical. This is correctly
reflected on the Host Summary page. However, this is not reflected on the Chassis Summary page. The server health is
displayed as warning. If the chassis was normal earlier, the health of the chassis also changes to warning.
Resolution/Workaround: None. This is a known defect in the RACADM. The defect will be fixed in the next release of
RACADM for chassis.
Version Affected: 3.0 and later
Issue 14: OMIVV plug-in might display the Download and Install status in some situations.
Description: After OMIVV is installed and registered with the vCenter Server, the status of OMIVV plug-in might not display the
Enabled status in some situations. The Download and Install status is displayed instead of the Enabled status.
Resolution/Workaround: If there are any concerns with registering the OMIVV plug-in, contact technical support.
Version Affected: 3.0 and later
Issue 15: The physical disk name is not displayed at datacenter and cluster level inventory in some situations.
Description: Although the physical disk name appears when you view the inventory at the host level, the physical disk name
appears empty when you view the inventory of the host at the datacenter and cluster level.
Resolution/Workaround: This issue does not affect the functionality of the features and you can view the inventory at the
host level to see the physical disk name.
Known Issues