Users Guide

Table Of Contents
26. Use the arrow keys to select Auto-Discovery.
27. Use the space bar to toggle the option to Enabled.
28. From your keyboard, press ESC.
29. Press ESC again.
Manually configuring PowerEdge 12th and later generation servers for auto
discovery
Ensure that you have an iDRAC address.
When you order servers from Dell, you can ask for the auto discovery feature to be enabled on the servers after you provide
the provisioning server IP address. The provisioning server IP address should be the IP address of OMIVV. Therefore, after you
receive the servers from Dell, when you power on the servers after mounting and connecting the iDRAC cable, the servers get
auto discovered and listed in the first page of the Deployment Wizard.
NOTE: For auto discovered servers, the credentials that are provided under Manage > Settings > Deployment
Credentials is set as admin credentials and is used for further communication with the server, until the OS deployment is
completed. After a successful OS deployment, the iDRAC credentials that are provided in the associated connection profile
are set.
To enable auto discovery manually on the target machine, perform the following steps for 12th and later generation servers:
1. To go to system setup, boot/reboot the target system and press F2 during the initial boot.
2. Go to iDRAC Settings > User Configuration and disable the root user. Ensure that there are no other users with active
administrator privileges on the iDRAC address when you are disabling the root user.
3. Click Back, and click Remote Enablement.
4. Set Enable Auto-Discovery as Enabled and Provisioning Server as the IP address of the OMIVV.
5. Save the settings.
The server is auto discovered upon next server boot. After successful auto discovery, the root user gets enabled, and the
Enable Auto-Discovery flag is disabled automatically.
Removing bare-metal server
You can manually remove a server that has been auto discovered or manually added.
1. In OpenManage Integration for VMware vCenter, click the Manage > Deployment tab.
2. In the Bare Metal Servers page, select the servers and click
.
Provisioning
All auto/manually discovered complaint bare-metal systems are available to OMIVV for hardware provisioning and hypervisor
deployment. To prepare for provisioning and deployment, do the following:
Table 34. Preparing for deployment
Steps Description
Create a hardware profile Contains the hardware settings gathered from a reference server that is used to deploy new
servers. See Customizing reference server to create hardware profile.
Create a hypervisor profile Contains the hypervisor installation information needed for ESXi deployment. See Creating a
hypervisor profile.
Create a deployment
template
Optionally contains a hypervisor profile, or both hardware and hypervisor profiles. You can save
and reuse these profiles as needed for all available data center servers.
NOTE: Only hardware profile deployment is not supported.
94 Deploying hypervisor