Users Guide

Table Of Contents
Why did system not enter maintenance mode when I performed
one-to-many firmware update?
Some firmware updates do not require rebooting the host. In that case, the firmware update is performed without putting the
host into maintenance mode.
Why is chassis global health still healthy when some of power
supply status has changed to critical?
The global health of the chassis about the power supply is based on the redundancy policies and whether the chassis power
needs are satisfied by the PSU that are still online and functional. So even if some of the PSU is out of power, the overall power
requirement of the chassis are met. So the global health of the chassis is Healthy. For more details on the Power Supply and
Power Management look in the users Guide for Dell PowerEdge M1000e Chassis Management Controller Firmware document.
Why is processor version displayed Not Applicable in processor
view in system overview page?
In PowerEdge 12
th
Generation Dell servers and higher generations, the processor version is in the Brand column. In lower
generation servers, processor version is shown in the Version column.
Why exception is returned when I click finish after editing
connection profile through web client?
This happens when the vCenter server is registered to the appliance through IP instead of FQDN. The connection profile can be
edited through the web client.
Resolution: Re-registering the vCenter server to the same appliance does not solve this. A new setup registered with FQDN is
required.
Why connection profiles to which host belongs to when I
create\edit connection profile in web GUI cannot be seen?
This happens when the vCenter server is registered to the appliance through IP instead of FQDN. Re-registering the vCenter
server to the same appliance does not solve this issue. A new setup registered with FQDN is required.
Why is select host window in web UI is blank on editing connection
profile?
This happens when the vCenter server is registered to the appliance through IP instead of FQDN. Re-registering the vCenter
server to the same appliance does not solve this issue. A new setup registered with FQDN is required.
Why error message is displayed after clicking firmware link?
If you have a slow network speed (9600BPS), you may get a communication error message. This error message may display
when you click the firmware link in the vSphere Client for the OpenManage Integration for VMware vCenter. It happens when
the connection times out while trying to obtain the software inventory list. Microsoft Internet Explorer initiates this time out. For
the Microsoft Internet Explorer versions 9/10, the default Receive Time out value is set to 10 seconds. Fix this issue by using
the following steps:
122