Release Notes
Table Of Contents
Resolution: Retry the test connection operation.
Version affected: All
● Issue 33–190572: In vCenter linked mode environment, cluster profile entry remains in OMIVV UI and API even after
unregistering vCenter and re-registering the same vCenter.
Resolution: Manually delete the cluster profile from OMIVV UI.
Version Affected: 5.3
● Issue 34– 194378: PowerEdge R820 host image is not displayed on the OMIVV Host Information page after successful
inventory.
Resolution: This issue does not affect the functionality of the features.
Version affected: 5.0 and later
● Issue 35– 194800: After backup and restore or RPM upgrade operation, Memory Page Retire (MPR) alarm is enabled on
the Alarm Definitions page of vCenter.
This issue occurs if you have enabled the alarms for all hosts and its chassis option in previous version of OMIVV. After you
perform restore or RPM upgrade, the same setting is applicable for MPR forecast alarm.
Resolution: Enable and disable MPR forecast alarms settings in OMIVV.
Version affected: 5.3
● Issue 36– 194306: Unable to detect the IDSDM in OMIVV during OS deployment
The IDSDM component is not detected under Installation Target section in OMIVV during OS deployment. However,
iDRAC can detect the IDSDM (not firmware version).
Resolution: Enable Remote RACADM in iDRAC Settings > Services and ensure that iDRAC responds information about
IDSDM to racadm getsensorinfo command.
Version affected: 5.3
● Issue 37– 195480: vCenter disables the DellEMC Proactive HA provider when you move the host that is not inventoried
successfully in OMIVV to Proactive HA enabled cluster.
Resolution: Ensure that the host is inventoried successfully before moving the host to Proactive HA enabled cluster. If the
host is moved without successful inventory, manually disable the Proactive HA provider and then enable it.
Version Affected: 5.3
● Issue 38– 195518: When you perform the cluster or host level firmware update on ESXi 7.0 U2 host having drivers, driver
installation status information in missing in the OMIVV logs.
Resolution: Run drift detection job to see the updated and deviated driver attributes.
Version affected: 5.3
● Issue 39– 195347: The iDRAC Expiration Date displays N/A on the Bare-Metal Servers page.
Resolution: This issue does not affect the functionality of the features. If the bare-metal server has valid license, OS
deployment job runs successfully.
Version affected: 5.0 and later
● Issue 40– 202646: After successful restore, if backed up OMIVV appliance and restored OMIVV appliance IP addresses are
different, an error message Cannot find hardware support package from depot is displayed when any vSphere
Lifecycle Manager action is performed.
When you perform backup and restore from an earlier version of OMIVV to a later version using the different OMIVV IP,
OMIVV is not displayed as a Hardware Support Manager in vSphere Lifecycle Manager. Therefore, check compliance and
remediation tasks fails with an error message Cannot find hardware support package from depot.
Resolution: Log in to OMIVV administration console, unregister, and register the vSphere Lifecycle Manager.
Version affected: 5.2 and later
14