Users Guide

Table Of Contents
Table 26. Virtualization events (continued)
Event name Description Severity Recommended action
Dell-Virtual Disk Partition
warning
Virtual disk partition warning Warning No action
iDRAC events
NOTE: For all Proactive HA enabled hosts that are part of a cluster, the following virtualization events are mapped to the
Proactive HA events; except events, "The fans are not redundant" and "The power supplies are not redundant" are not
mapped.
The fans are redundant None Info No action
Fan redundancy is lost One of more fans have
failed or have been removed
or a configuration change
occurred, which requires
additional fans
Critical Remove and reinstall failed
fans or install additional fans
Fan redundancy is degraded One of more fans have
failed or have been removed
or a configuration change
occurred, which requires
additional fans.
Warning Remove and reinstall failed
fans or install additional fans
The fans are not redundant One of more fans have
failed or have been removed
or a configuration change
occurred, which requires
additional fans
Info Remove and reinstall failed
fans or install additional fans
The fans are not redundant.
Insufficient resources to
maintain normal operations
One of more fans have
failed or have been removed
or a configuration change
occurred, which requires
additional fans
Critical Remove and reinstall failed
fans or install additional fans
The power supplies are
redundant
None Info No action
Power supply redundancy is
lost
The current power
operational mode is non-
redundant because of a
power supply exception,
a power supply inventory
change, or a system power
inventory change. The system
was previously operating in a
power redundant mode
Critical Check the event log for
power supply failures. Review
system configuration and
power consumption
Power supply redundancy is
degraded
The current power
operational mode is non-
redundant because of a
power supply exception,
a power supply inventory
change, or a system power
inventory change. The system
was previously operating in a
power redundant mode
Warning Check the event log for
power supply failures. Review
system configuration and
power consumption
The power supplies are not
redundant
The current power supply
configuration does not meet
the platform requirements to
enable redundancy. If a power
supply fails the system may
shut down.
Info If unintended, review system
configuration and power
consumption and install power
supplies accordingly. Check
power supply status for
failures
78 Events, alarms, and health monitoring