Users Guide

Table Of Contents
Table 26. Virtualization events
Event name Description Severity Recommended action
occurred, which requires
additional fans
Fan redundancy is degraded One of more fans have
failed or have been removed
or a configuration change
occurred, which requires
additional fans.
Warning Remove and reinstall failed
fans or install additional fans
The fans are redundant None Info No action
The fans are not redundant One of more fans have
failed or have been removed
or a configuration change
occurred, which requires
additional fans
Info Remove and reinstall failed
fans or install additional fans
The fans are not redundant.
Insufficient resources to
maintain normal operations
One of more fans have
failed or have been removed
or a configuration change
occurred, which requires
additional fans
Critical Remove and reinstall failed
fans or install additional fans
Proactive HA events
Based on the components supported by VMware for Proactive HA, the following events are registered by the Dell Inc provider
during its registration with vCenter:
NOTE:
The Proactive HA health status of the supported components can be normal (green), or warning (yellow), or critical
(red), or unknown (gray) state.
Table 27. Dell Proactive HA events
Dell Inc provider event Component type Description
DellFanRedundancy Fan Fan redundancy event
DellPowerRedundancy Power supply (PSU) Power redundancy event
DellIDSDMRedundancy Storage IDSDM redundancy event
For a Proactive HA enabled host, the following Traps are used by OMIVV as a trigger to determine the redundant health of
components: Based on the redundant health information, a Proactive HA health update might be sent to the vCenter for that
host. These Traps are not forwarded directly to a vCenter for a Proactive HA host.
Table 28. Proactive HA events
Event name Description Severity
Fan Information Fan information Info
Fan Warning Fan warning Warning
Fan Failure Fan failure Critical
Power Supply Normal The power supply returns to normal Info
Power Supply Warning The power supply detects a warning Warning
Power Supply Failure The power supply detects a failure Critical
Power Supply Absent The power supply is absent Critical
Redundancy Information Redundancy information Info
Redundancy Degraded Redundancy is degraded Warning
Events, alarms, and health monitoring 83