Users Guide

Table Of Contents
Table 26. Virtualization events (continued)
Event name Description Severity Recommended action
The power supplies are
not redundant. Insufficient
resources to maintain normal
operations
The system may power down
or operate in a performance
degraded state
Critical Check the event log for
power supply failures. Review
system configuration and
power consumption and
upgrade or install power
supplies accordingly
Internal Dual SD Module is
redundant
None Info No action
Internal Dual SD Module
redundancy is lost
Either one of the SD card or
both the SD cards are not
functioning properly
Critical Replace the failed SD card
Internal Dual SD Module
redundancy is degraded
Either one of the SD card or
both the SD cards are not
functioning properly
Warning Replace the failed SD card
Internal Dual SD Module is not
redundant
None Info Install additional SD card and
configure for redundancy if
redundancy is desired
Chassis events
Power supply redundancy is
lost
The current power
operational mode is non-
redundant because of a
power supply exception,
a power supply inventory
change, or a system power
inventory change. The system
was previously operating in a
power redundant mode
Critical Check the event log for
power supply failures. Review
system configuration and
power consumption
Power supply redundancy is
degraded
The current power
operational mode is non-
redundant because of a
power supply exception,
a power supply inventory
change, or a system power
inventory change. The system
was previously operating in a
power redundant mode
Warning Check the event log for
power supply failures. Review
system configuration and
power consumption
The power supplies are
redundant
None Info No action
The power supplies are not
redundant
The current power supply
configuration does not meet
the platform requirements to
enable redundancy. If a power
supply fails the system may
shut down.
Info If unintended, review system
configuration and power
consumption and install power
supplies accordingly. Check
power supply status for
failures
The power supplies are
not redundant. Insufficient
resources to maintain normal
operations
The system may power down
or operate in a performance
degraded state
Critical Check the event log for
power supply failures. Review
system configuration and
power consumption and
upgrade or install power
supplies accordingly
Fan redundancy is lost One of more fans have
failed or have been removed
or a configuration change
Critical Remove and reinstall failed
fans or install additional fans
82 Events, alarms, and health monitoring