Users Guide

Table Of Contents
Table 26. Virtualization events (continued)
Event name Description Severity Recommended action
Dell-Fan enclosure removed
from system
A fan enclosure has been
removed from the specified
system
Warning No action
Dell-Fan enclosure removed
from system for an extended
amount of time
A fan enclosure has been
removed from the specified
system for a user-definable
length of time
Error No action
Dell-Fan enclosure sensor
detected a non-recoverable
value
A fan enclosure sensor in the
specified system detected an
error from which it cannot
recover
Error No action
Dell-AC power has been
restored
Sensor Returned to Normal
Value
Info No action
Dell-AC power has been lost
warning
An AC power cord has lost its
power, but there is sufficient
redundancy to classify this as
a warning
Warning No action
Dell-An AC power cord has
lost its power
An AC power cord has
lost its power, and lack of
redundancy requires this to
be classified as an error
Error No action
Dell-Processor sensor
returned to a normal value
Sensor Returned to Normal
Value
Info No action
Dell-Processor sensor
detected a warning value
A processor sensor in the
specified system is in a
throttled state
Warning No action
Dell-Processor sensor
detected a failure value
A processor sensor in the
specified system is disabled,
has a configuration error, or
experienced a thermal trip
Error No action
Dell-Processor sensor
detected a non-recoverable
value
A processor sensor in the
specified system has failed.
Error No action
Dell-Device configuration
error
A configuration error was
detected for a pluggable
device in the specified system
Error No action
Dell-Battery sensor returned
to a normal value
Sensor Returned to Normal
Value
Info No action
Dell-Battery sensor detected
a warning value
A battery sensor in the
specified system detected
that a battery is in a
predictive failure state
Warning No action
Dell-Battery sensor detected
a failure value
A battery sensor in the
specified system detected
that a battery has failed
Error No action
Dell-Battery sensor detected
a nonrecoverable value
A battery sensor in the
specified system detected
that a battery has failed
Error No Action
Dell-Thermal shutdown
protection has been initiated
This message is generated
when a system is configured
for thermal shutdown due
Error No action
Events, alarms, and health monitoring 77