Users Guide

Table Of Contents
Virtualization-related events
The following table contains the virtualization-related critical and warning events, and includes event name, description, severity
level, and recommended action.
Table 26. Virtualization events
Event name Description Severity Recommended action
Dell-Current sensor detected
a warning value
A current sensor in the
specified system exceeded its
warning threshold
Warning No action
Dell-Current sensor detected
a failure value
A current sensor in the
specified system exceeded its
failure threshold
Error Put the system into
maintenance mode
Dell-Current sensor detected
a non-recoverable value
A current sensor in the
specified system detected an
error from which it cannot
recover
Error No action
Dell-Redundancy regained Sensor Returned to Normal
Value
Info No action
Dell-Redundancy degraded A redundancy sensor in the
specified system detected
that one of the components
of the redundancy unit has
failed but the unit is still
redundant
Warning No action
Dell-Redundancy lost A redundancy sensor in the
specified system detected
that one of the components
in the redundant unit has
been disconnected, has failed,
or is not present
Error Put the system into
maintenance mode
Dell-Power supply returned to
normal
Sensor returned to Normal
Value
Info No action
Dell-Power supply detected a
warning
A power supply sensor
reading in the specified
system exceeded a user
definable warning threshold
Warning No action
Dell-Power supply detected a
failure
A power supply has been
disconnected or has failed
Error Put the system into
maintenance mode
Dell-Power supply sensor
detected a non-recoverable
value
A power supply sensor in the
specified system detected an
error from which it cannot
recover
Error No action
Dell-Memory Device Status
warning
A memory device correction
rate exceeded an acceptable
value
Warning No action
Dell-Memory Device error A memory device correction
rate exceeded an acceptable
value, a memory spare bank
was activated, or a multibit
ECC error occurred
Error Put the system into
maintenance mode
Dell-Fan enclosure inserted
into system
Sensor returned to normal
value
Info No action
76 Events, alarms, and health monitoring