Users Guide
Table Of Contents
- OpenManage Integration for VMware vCenter Version 4.1 Web Client User's Guide
- Introduction
- About Administration Console
- Using Administration Portal
- Registering vCenter server by non-administrator user
- Registering a vCenter server
- Uploading license to Administration Portal
- Managing the virtual appliance
- Restarting virtual appliance
- Changing host name of virtual appliance
- Updating virtual appliance repository location and virtual appliance
- Upgrading OMIVV from existing version to current version
- Updating appliance through backup and restore
- Downloading the troubleshooting bundle
- Setting up HTTP proxy
- Setting up Network Time Protocol (NTP) servers
- Configuring deployment mode
- Generating Certificate Signing Request
- Uploading HTTPS certificate
- Setting up global alerts
- Managing backup and restore
- About vSphere client console
- Using Administration Portal
- Managing multiple appliances
- Accessing OpenManage Integration from web client
- OpenManage Integration for VMware vCenter licensing
- Appliance configuration for VMware vCenter
- Profiles
- Inventory and warranty management
- About firmware updates
- Events, alarms, and health monitoring
- Chassis management
- Deploying hypervisor
- About host, bare-metal, and iDRAC compliance
- Security roles and permissions
- Troubleshooting
- Frequently Asked Questions (FAQ)
- Why Export All button fails to export to .CSV file in Google chrome?
- iDRAC license type and description are displayed incorrectly for non-compliant vSphere hosts
- Dell EMC icon is not displayed after unregistering vCenter from earlier OMIVV version and then registering same vCenter with later OMIVV version
- Configuration wizard settings are overridden by default settings each time it is invoked
- Dell provider is not displayed as health update provider
- Why is inventory failing when performing firmware update task on ESXi 5.x host?
- Host inventory or test connection fails due to invalid or unknown iDRAC IP. How can I get a valid iDRAC IP?
- On running fix noncompliant vSphere hosts wizard, why the status of a specific host is displayed as "Unknown"?
- Dell privileges that are assigned while registering the OMIVV appliance are not removed after unregistering OMIVV
- Dell Management Center does not display all the relevant logs when trying to filter a severity category. How can I view all the logs?
- How do I resolve error code 2000000 caused by VMware Certificate Authority (VMCA)?
- In Administration Console, why Update Repository Path is not set to default path after I reset appliance to factory settings?
- Why warranty and inventory schedule for all vCenters is not applying when selected from the job queue page?
- What should I do when a web communication error in the vCenter web client appears after changing the DNS settings in OMIVV?
- Why does the settings page fail to load, if I navigate away and again go back to the settings page?
- Why “Task cannot be scheduled for the time in the past” error in inventory schedule/warranty schedule page of Initial Configuration Wizard appear?
- Why installation date appears as 12/31/1969 for some of the firmware on the firmware page?
- Successive global refresh cause exception to be thrown in the recent task window. How can I resolve the error?
- Why is web client UI distorted for few Dell screens in IE 10?
- Why am I not seeing OpenManage Integration icon in web client even if registration of plug-in to vCenter was successful?
- Even if repository has bundles for selected 11G system, why is firmware update displaying that there are no bundles for firmware update?
- Why is DNS configuration settings restored to original settings after appliance reboot if appliance IP and DNS settings are overwritten with DHCP values
- Using OMIVV to update the Intel network card with firmware version of 13.5.2 is not supported
- Using OMIVV to update Intel network network card from 14.5 or 15.0 to 16.x fails due to staging requirement from DUP
- Why trying firmware update with invalid DUP, hardware update job status on vCenter console neither fails nor times-out for hours, although job status in LC prompts as ‘FAILED’?
- Why does Administration Portal display unreachable update repository location?
- Why did system not enter maintenance mode when I performed one-to-many firmware update?
- Why is chassis global health still healthy when some of power supply status has changed to critical?
- Why is processor version displayed “Not Applicable” in processor view in system overview page?
- What generation of Dell servers does OMIVV configure and support for SNMP traps?
- What vCenter servers are managed by OMIVV?
- Does OMIVV support vCenter in linked mode?
- What are required port settings for OMIVV?
- Why is password not changed for user used for bare-metal discovery after successfully applying hardware profile or system profile that has same user with new changed credentials in iDRAC user list?
- Why am I unable to view new iDRAC version details listed on vCenter hosts and clusters page?
- How can I test event settings by using OMSA to simulate temperature hardware Fault?
- Although OMSA agent is installed on OMIVV host system, I still get error message that OMSA is not installed. How do I resolve this error?
- Can OMIVV support ESXi with lockdown mode enabled?
- When I tried to use lockdown mode, it fails
- What do I do if creation of hardware profile fails if I am using reference server?
- Why attempting to deploy ESXi on server fails?
- Why hypervisor deployments failing on Dell PowerEdge R210 II machines?
- Why auto discovered systems are displayed without model information in Deployment wizard?
- NFS share is set up with ESXi ISO, but deployment fails with errors mounting share location
- How do I force removal of virtual appliance?
- Entering a Password in the Backup Now Screen Receives an Error Message
- In vSphere web client, clicking Dell server management portlet or Dell icon returns 404 error
- What should I do as firmware update failed?
- What should I do as vCenter registration failed?
- Performance during connection profile test credentials is slow or unresponsive
- Does OMIVV support VMware vCenter server appliance?
- Why is firmware level not updated when I have performed firmware update with Apply on Next reboot option and system was rebooted?
- Why is host still displayed under chassis even after removing host from vCenter tree?
- In Administration Console, why Update Repository Path is not set to default path after I reset appliance to factory settings?
- After backup and restore of OMIVV, why alarm settings are not restored?
- Hypervisor deployment fails when NIC Partitioning (NPAR) is enabled on a target node and disabled in System Profile
- Available virtual appliance version displays wrong information when the available version is lesser than the current version
- Bare-metal deployment issues
- Frequently Asked Questions (FAQ)
- Related Documentation
- System specific attributes
- Customization attributes
- Additional information
5. Click Next.
6. In the Select Template/Profile page, perform the following substeps:
a. Under Deployment Template, to assign a deployment template to the selected servers, select an existing deployment
template from Select Deployment Template.
NOTE: System profile based template is displayed only if you select the 14th generation servers on the Select the
servers for deployment page.
You can select one of the following deployment templates from the drop-down list:
● If you select a hardware profile only or system profile only deployment template that only configures server hardware,
go to step 10.
● If you select hypervisor profile deployment template that deploys a hypervisor, continue from step 6 (b) onwards.
NOTE: If you select hardware profile or system profile only deployment, you are automatically prompted to
include information for the Schedule Deployment page.
b. Under Hypervisor Installation, select either of the following options:
● First boot disk—deploys a hypervisor on the Hard Disk (HDD), Solid State Drive (SSD), Virtual disk created by RAID
controllers.
● Internal Dual SD Module—deploys a hypervisor on the IDSDM.
NOTE: If an IDSDM is available on at least one of the selected servers, the Internal Dual SD Module option is
enabled. If not, only the Hard Disk option is available.
If any of the selected servers do not support an IDSDM, or an IDSDM is not present during deployment, perform one
of the following actions:
○ Select Deploy the hypervisor to the first boot disk for servers that do not have an available Internal Dual
SD Module check box, if you want to deploy a hypervisor on the first boot disk of the servers.
CAUTION:
If you select this option and deploy the hypervisor on the first boot disk drive of the
servers, all the data on the disk drives are erased.
○ To skip the deployment on the selected servers and continue with hypervisor deployment on the next server, clear
Deploy the hypervisor to the first boot disk for servers that do not have an available Internal Dual SD
Module.
c. Under Credential Profile, perform either of the following actions:
● Select the Use this Credential Profile for all Servers option button, and to assign all servers to the same existing
profile, select the connection profile from the drop-down list.
● Click the Select a Connection Profile for each Server option button, and then select an individual connection
profile for each server from the drop-down list.
7. Click Next.
The Server Identification page is displayed.
The server identification can be provided in two ways:
● Enter networking information (IP address, subnet mask, and gateway)—a fully qualified domain name for the host name
is mandatory. The use of localhost for the FQDN is not supported. The FQDN is used when adding the host to vCenter.
● Use Dynamic Host Configuration Protocol (DHCP) to configure IP addresses, subnet mask, gateway IP, host name, and
preferred/alternate DNS servers—the DHCP assigned IP address is used when adding the host to vCenter. When using
DHCP, it is recommended that an IP reservation for selected NIC MAC addresses is used.
NOTE:
Use a Fully Qualified Domain Name (FQDN) for host name instead of localhost. Starting with ESXi 5.1, a value
of localhost impairs the OMIVV plug-in from processing events sent from the host. Create a DNS record that resolves
the IP address with the FQDN. For SNMP alerts from ESXi 5.1 to be identified correctly, configure the DNS server to
support reverse lookup requests. The DHCP reservations and DNS host names must be in place and verified before the
deployment job is scheduled to run.
8. In the Server Identification page, do the following:
The page provides the option to specify a VLAN ID. When a VLAN ID is provided, it is applied to the management interface
of hypervisor during deployment and tags all traffic with the VLAN ID. Server Identification assigns new names and network
identification to deployed servers. See VLAN support.
a. To expand and view individual server information, under Selected Servers, click .
b. Under Host Name and NIC, enter a Fully Qualified Host Name for the server.
c. In the NIC for Management Tasks drop-down list, select the NIC for managing the server.
d. Enter IP addresses, subnet mask, default gateway, and DNS details, or select the Obtain using DHCP check box.
e. If deploying to a network that requires a VLAN ID, select the VLAN check box and then enter the VLAN ID.
106
Deploying hypervisor