Users Guide

Table Of Contents
Why trying firmware update with invalid DUP, hardware update job
status on vCenter console neither fails nor times-out for hours,
although job status in LC prompts as FAILED
When the invalid DUP is picked for firmware update, the status of the task in the vCenter console window remains In Progress
but the message is changed to the reason of failure. This is a known VMware defect and will be fixed in the future releases of
VMware vCenter.
Resolution: The task must be canceled manually.
Version Affected: All
Why does Administration Portal display unreachable update
repository location
If you provide an unreachable Update Repository path, the Failed: Error while connecting to the URL. error message is
displayed on the top of the Appliance Update view. However, the Update Repository Path is not cleared to the value before
update.
Resolution: Move out of this page to another page and ensure that the page is refreshed.
Version Affected: All
Why did system not enter maintenance mode when I performed
one-to-many firmware update
Some firmware updates do not require rebooting the host. In that case, the firmware update is performed without putting the
host into maintenance mode.
Chassis global health still healthy when some of power supply
status has changed to critical
The global health of the chassis about the power supply is based on the redundancy policies and whether the chassis power
needs are satisfied by the PSU that are still online and functional. So even if some of the PSU is out of power, the overall power
requirement of the chassis are met. So the global health of the chassis is Healthy. For more details on the Power Supply and
Power Management look in the users Guide for Dell PowerEdge M1000e Chassis Management Controller Firmware document.
Processor version is displayed as Not Applicable in processor
view in system overview page
In PowerEdge 12
th
Generation Dell servers and higher generations, the processor version is in the Brand column. In lower
generation servers, processor version is shown in the Version column.
Does OMIVV support vCenter in linked mode
Yes, OMIVV supports up to 10 vCenter servers either in a linked mode or not in a linked mode. For more information about how
OMIVV works in linked mode, see the white paper, OpenManage Integration for VMware vCenter: Working in Linked Mode at
www.dell.com.
142
Frequently Asked Questions-FAQ