Users Guide

Table Of Contents
Resolution: Ensure that the host is compliant using the host Compliance screen of OpenManage Integration desktop client. If it
is not compliant, use the fix Host Compliance to get it compliant.
Version Affected: 2.2 and later
Why Does My ESXi Deployment Fail on Servers Having a PERC
S300 Boot Controller?
Deployments of OpenManage Integration for VMware vCenter using different ESXi versions on Dell PowerEdge servers with the
PERC S300 boot controller failed. The Dell customized ESXi operating systems do not carry the driver for the PERC S300 boot
controller, which causes the boot controller/HDD not to be recognized during operating system installation. Servers with PERC
S300 boot controllers are not supported for OpenManage Integration for VMware vCenter deployments.
How Come I See An Error Message Displayed After Clicking The
Firmware Link?
If you have a slow network speed (9600BPS), you may get a Communication Error Message. This error message may display
when you click the Firmware link in the vSphere Client for the OpenManage Integration for VMware vCenter. It happens when
the connection times out while trying to obtain the Software Inventory list. Microsoft Internet Explorer initiates this timeout. For
Microsoft Internet Explorer versions 9/10, the default Receive Time out value is set to 10 seconds. Fix this issue by using the
following steps.
Figure 5. Firmware link communication error
1. Open Microsoft Registry Editor (Regedit).
2. Navigate to the following location:
KHEY_CURRENT_USER\Software\Microsoft\Windows\CurrentVersion\Internet Settings
3. Add a DWORD value for ReceiveTimeout.
4. Set the value to 30 seconds (30000) [This value may need to be a higher value in your environment].
5. Exit Regedit.
6. Restart Internet Explorer.
NOTE: Just opening a new Internet Explorer window is not enough. Restart the Internet Explorer browser.
What generation of Dell servers does the OpenManage Integration
for VMware vCenter configure and support for SNMP traps?
OpenManage Integration for VMware vCenter supports OMSA SNMP traps on pre-12th generation servers and iDRAC traps on
12th generation servers.
Troubleshooting
77