Users Guide

Table 9. Virtualization events (continued)
Event name Description Severity Recommended action
Dell-
alertStorageSoftwareDefinedSubSystemWa
rning
Software defined
storage subsystem
warning
Warning No action
Dell-alertTemperatureProbeReadWarning Unable to read
Temperature
Sensors
Warning No action
Dell-alertTemperatureProbeChangeFailure Temperature
increase Error
Critical Check the chassis event log for fan issues
and fix any issues present. If fan issues
are not detected, check chassis ambient
temperature and make sure the
temperature is within operating range. To
check the chassis ambient temperature,
run the following RACADM command:
racadm getsensorinfo.
Dell-Current sensor detected a warning
value
A current sensor in
the specified system
exceeded its
warning threshold
Warning No action
Dell-Current sensor detected a failure value A current sensor in
the specified system
exceeded its failure
threshold
Error Put the system into maintenance mode
Dell-Current sensor detected a non-
recoverable value
A current sensor in
the specified system
detected an error
from which it cannot
recover
Error No action
Dell-Redundancy regained Sensor Returned to
Normal Value
Info No action
Dell-Redundancy degraded A redundancy sensor
in the specified
system detected
that one of the
components of the
redundancy unit has
failed but the unit is
still redundant
Warning No action
Dell-Redundancy lost A redundancy sensor
in the specified
system detected
that one of the
components in the
redundant unit has
been disconnected,
has failed, or is not
present
Error Put the system into maintenance mode
Dell-Power supply returned to normal Sensor returned to
Normal Value
Info No action
Dell-Power supply detected a warning A power supply
sensor reading in the
specified system
exceeded a user
definable warning
threshold
Warning No action
94 Manage vCenter settings