Users Guide
NOTE: When the OMIVV appliance is not able to retrieve an IP address from the network (DHCP), 0.0.0.0 is
displayed as the IP address. To resolve this, you must manually configure the static IP.
a. On the Date and Time tab, select the Synchronize date and time over the network check box. The Synchronize
date and time over the network check box is enabled only after NTP is configured successfully using the Admin portal.
For more information about configuring NTP, see Set up Network Time Protocol (NTP) servers on page 22.
b. Click Time Zone and select the applicable time zone, and then click OK.
6. To configure network of the OMIVV appliance, click Network Configuration.
To manage the Dell EMC servers in your vSphere environment, OMIVV requires access to both the vSphere network
(vCenter and ESXi management network) and out-of-band network (iDRAC, CMC, and OME-Modular).
If vSphere network and out-of-band network are maintained as separate isolated network in your environment, OMIVV
requires access for both the networks. In this case, OMIVV appliance must be configured with two network adapters. It is
recommended that you configure both the networks as part of the initial configuration.
If you can access the out-of-band network using the vSphere network, do not configure two network adapters for the
OMIVV appliance. For more information about configuring a second NIC, see Configure OMIVV appliance with two Network
Interface Controllers (NICs) on page 28.
7.
Select Wired Connection 1 and click
.
26
Log in to Dell EMC OMIVV administration console