Password is not changed for user used for bare-metal discovery
after successfully applying system profile that has same user with
new changed credentials in iDRAC user list
The password of the user who is used from discovery is not changed to the new credential if only System Profile (Configuration
of the hardware) is selected for deployment. This is done intentionally so that the plug-in can communicate with the iDRAC for
future use in deployment needs.
Unable to view new iDRAC version details listed on vCenter hosts
and clusters page
Resolution: After successful completion of a firmware update task in the vSphere web client, refresh the Firmware Update
page and verify the firmware versions. If the page displays the old versions, go to the Host Compliance page in OpenManage
Integration for VMware vCenter, and check the CSIOR status of that host. If CSIOR is not enabled, enable CSIOR and reboot
host. If CSIOR is already enabled, log in to the iDRAC console, reset iDRAC, wait for few minutes, and then refresh the
Firmware Update page.
Can OMIVV support ESXi with lockdown mode enabled
Yes, lockdown mode is supported in this Release on hosts ESXi 6.0 and later.
When I tried to use lockdown mode, it fails
When I added a host to the host credential profile in lockdown mode, the inventory started, but failed stating that No Remote
Access Controller was found or Inventory is not supported on this host.
If you put the host in lockdown mode or remove a host from lockdown mode, ensure that you wait for 30minutes before
performing the next operation in OMIVV.
Attempting to deploy ESXi on server fails
1. Ensure that the ISO location (NFS path) and staging folder paths are accurate.
2. Ensure that the NIC selected during assignment of server identity is accessible by the virtual appliance.
3. Ensure that you select the management NICs based on the network connectivity to the OMIVV.
4. If using static IP address, ensure that the network information provided (including subnet mask and Default Gateway) is
accurate. Also, ensure that the IP address is not already assigned on the network.
5. Ensure that at least one Virtual Disk, or IDSDM, or BOSS is seen by the system.
Auto discovered systems are displayed without model information
in Deployment wizard
This usually indicates that the firmware version that is installed on the system does not meet the recommended minimum
requirements. Sometimes, a firmware update may not have registered on the system.
Resolution: Cold booting the system or reseating the Blade fixes this issue. The newly enabled account on the iDRAC must be
disabled, and auto discovery reinitiated to provide model information and NIC information to OMIVV.
NFS share is set up with ESXi ISO, but deployment fails with errors
mounting share location
To find the solution:
Frequently Asked Questions-FAQ