Users Guide

Table 9. Virtualization events (continued)
Event name Description Severity Recommended action
because of a power
supply exception, a
power supply
inventory change, or
a system power
inventory change.
The system was
previously operating
in a power
redundant mode
Power supply redundancy is degraded The current power
operational mode is
non-redundant
because of a power
supply exception, a
power supply
inventory change, or
a system power
inventory change.
The system was
previously operating
in a power
redundant mode
Warning Check the event log for power supply
failures. Review system configuration and
power consumption
The power supplies are redundant None Info No action
The power supplies are not redundant The current power
supply configuration
does not meet the
platform
requirements to
enable redundancy.
If a power supply
fails the system may
shut down.
Info If unintended, review system configuration
and power consumption and install power
supplies accordingly. Check power supply
status for failures
The power supplies are not redundant.
Insufficient resources to maintain normal
operations
The system may
power down or
operate in a
performance
degraded state
Critical Check the event log for power supply
failures. Review system configuration and
power consumption and upgrade or install
power supplies accordingly
Fan redundancy is lost One of more fans
have failed or have
been removed or a
configuration
change occurred,
which requires
additional fans
Critical Remove and reinstall failed fans or install
additional fans
Fan redundancy is degraded One of more fans
have failed or have
been removed or a
configuration
change occurred,
which requires
additional fans.
Warning Remove and reinstall failed fans or install
additional fans
The fans are redundant None Info No action
The fans are not redundant One of more fans
have failed or have
been removed or a
Info Remove and reinstall failed fans or install
additional fans
102 Manage vCenter settings