Table 9. Virtualization events (continued)
Event name Description Severity Recommended action
Dell-Power usage audit failure or critical
event
Power usage audit
failure or critical
event
Error Put the system into maintenance mode
Dell-Security configuration warning Security
configuration
warning
Warning No action
Dell-Configuration: Software configuration
warning
Configuration:
Software
configuration
warning
Warning No action
Dell-Configuration: Software configuration
failure
Configuration:
Software
configuration failure
Error Put the system into maintenance mode
Dell-Virtual Disk Partition failure Virtual disk partition
failure
Error Put the system into maintenance mode
Dell-Virtual Disk Partition warning Virtual disk partition
warning
Warning No action
iDRAC events
NOTE: For all Proactive HA enabled hosts that are part of a cluster, the following virtualization events are mapped to the
Proactive HA events; except events, "The fans are not redundant" and "The power supplies are not redundant" are not
mapped.
The fans are redundant None Info No action
Fan redundancy is lost One of more fans
have failed or have
been removed or a
configuration
change occurred,
which requires
additional fans
Critical Remove and reinstall failed fans or install
additional fans
Fan redundancy is degraded One of more fans
have failed or have
been removed or a
configuration
change occurred,
which requires
additional fans.
Warning Remove and reinstall failed fans or install
additional fans
The fans are not redundant One of more fans
have failed or have
been removed or a
configuration
change occurred,
which requires
additional fans
Info Remove and reinstall failed fans or install
additional fans
The fans are not redundant. Insufficient
resources to maintain normal operations
One of more fans
have failed or have
been removed or a
configuration
change occurred,
which requires
additional fans
Critical Remove and reinstall failed fans or install
additional fans
The power supplies are redundant None Info No action
100 Manage vCenter settings