Release Notes

Issue 28: Configuring the System Lockdown mode at a cluster level sometimes displays a message "No hosts under the
cluster has successful inventory."
Description: Configuring the System Lockdown mode at a cluster level sometimes displays a message "No hosts under the
cluster has successful inventory." This message is displayed even when the cluster has successfully inventoried the 14G
hosts that are managed by OMIVV.
Resolution: Reboot the vCenter.
To reboot the vCenter, do the following:
1. Log in to the vSphere Client with a vCenter Single Sign-on Administrator account.
2. Go to Administration > Deployment > Deployment > System Configuration.
3. Click Nodes, select the vCenter Server Appliance node, and click the Related Objects tab.
4. Reboot the vCenter node.
Version Affected: 4.3 and later
Issue 29: Sometimes post RPM upgrade of OMIVV appliance, multiple entries in the logs are seen in vCenter Recent Tasks.
Description: Sometimes, after RPM upgrade, multiple entries are displayed in logs when viewed on vCenter Recent Tasks.
Resolution: Restart the vCenter services.
Version Affected: 4.3 and later
Issue 30: Sometimes, the storage inventory data is not displayed for the host managed using chassis credential profile and
present in member chassis.
Description: The storage data may not be displayed for an MX host managed using the chassis credential profile and for a
host present in the member chassis. Though the inventory data of other components is displayed, only the storage-related
data is not displayed
Resolution: Do one of the following:
1. Update the MX7000 chassis firmware version to 1.00.10.
2. Manage the host using iDRAC.
3. Reinstall the host in another slot of the same MX7000 chassis and retry the operation.
Version Affected: 4.3 and later
Issue 31148132: For a non-administrator user, inventory fails indicating that the enabling WBEM service is failed on host.
Resolution: For more information about the required privilege for non-administrator user, see the OMIVV 5.0 User's Guide.
Assign the required privilege to user and run the inventory again.
Version Affected: 5.0
Issue 32147023: Host firmware update fails, if a canceled firmware update job of related chassis is present.
If you cancel the firmware update job of a PowerEdge MX chassis, subsequent host firmware update job for hosts present in
the same chassis is blocked.
Resolution: Purge the canceled chassis firmware update job to release the lock on the related hosts.
Version Affected: 5.0
Issue 33143173: OMIVV page displays invalid session, or time out exception, or two million errors in Firefox browser.
If the OMIVV page is idle for some time (510 minutes), the invalid session, or time out exception, or two million errors is
displayed.
Resolution: Refresh the browser. If the issue persists, log out and log in from vCenter.
To see the correct data in OMIVV, ensure that you complete the task listed in resolution.
Version Affected: 5.0
Issue 34148838: Unable to delete the ISO profile.
Resolution: None. You can edit the profile and use the same profile for different deployment task.
Version Affected: 5.0
Issue 35156807: Invalid task name might be displayed for OMIVV tasks under VMware Task Console.
Resolution: None
Known issues
13