API Guide

Get host or cluster firmware update job details
Table 48. Response body
Field Type Description
id String Firmware update job ID or host ID
status String Status of the firmware update job
jobname String Firmware update job name
jobdesc String Firmware update job description
updateType String Update type
runNow Boolean Run update job now
runLater Boolean Run update job later
dateTime Integer and String Update job schedule date and time
repoProfileID String Firmware repository profile ID
hostip String Host IPv4 or FQDN
hostName String Hostname
managementIP String IDRAC IP
serviceTag String Host Service Tag
model String Server Model
systemId String System ID
bundleId String Bundle ID
packageIDs String Component unique package ID
rebootOptions String Reboot options.
Safe reboot: Apply Updates and Reboot
after entering Maintenance mode.
Applicable for cluster level, vSphere,
vSAN, and datacenter host level.
Next reboot: Apply updates on next
reboot. Applicable for vSphere,
datacenter, and vSAN host level.
Force reboot: Apply updates and force
reboot without entering maintenance
mode. Applicable for vSphere and
datacenter host level.
precheck Boolean Prerequisites check before firmware
update.
Ensure that prerequisites checks are met
in your environment:
For vSAN host and cluster:
DRS is enabled
Host is not already in maintenance mode
vSAN data objects are healthy
For vSphere host and cluster: DRS is
enabled
44 Response body