Users Guide
Event name Description Severity Recommended action
Dell-Memory Device Status
warning
A memory device correction
rate exceeded an acceptable
value
Warning No action
Dell-Memory Device error A memory device correction
rate exceeded an acceptable
value, a memory spare bank was
activated, or a multibit ECC
error occurred
Error Put the system into
maintenance mode
Dell-Fan enclosure inserted into
system
Sensor returned to normal value Info No action
Dell-Fan enclosure removed
from system
A fan enclosure has been
removed from the specified
system
Warning No action
Dell-Fan enclosure removed
from system for an extended
amount of time
A fan enclosure has been
removed from the specified
system for a user-definable
length of time
Error No action
Dell-Fan enclosure sensor
detected a non-recoverable
value
A fan enclosure sensor in the
specified system detected an
error from which it cannot
recover
Error No action
Dell-AC power has been
restored
Sensor Returned to Normal
Value
Info No action
Dell-AC power has been lost
warning
An AC power cord has lost its
power, but there is sufficient
redundancy to classify this as a
warning
Warning No action
Dell-An AC power cord has lost
its power
An AC power cord has lost its
power, and lack of redundancy
requires this to be classified as
an error
Error No action
Dell-Processor sensor returned
to a normal value
Sensor Returned to Normal
Value
Info No action
Dell-Processor sensor detected
a warning value
A processor sensor in the
specified system is in a throttled
state
Warning No action
Dell-Processor sensor detected
a failure value
A processor sensor in the
specified system is disabled, has
a configuration error, or
experienced a thermal trip
Error No action
Dell-Processor sensor detected
a non-recoverable value
A processor sensor in the
specified system has failed.
Error No action
Dell-Device configuration error A configuration error was
detected for a pluggable device
in the specified system
Error No action
Dell-Battery sensor returned to
a normal value
Sensor Returned to Normal
Value
Info No action
Dell-Battery sensor detected a
warning value
A battery sensor in the specified
system detected that a battery
is in a predictive failure state
Warning No action
Manage vCenter settings 83