Users Guide

Compliance
Management Compliance
To view and manage hosts in OMIVV, each host must meet certain criteria. If the hosts do not meet the compliance criteria, OMIVV will
not manage and monitor them. OMIVV displays details about the noncompliance host, and enables you to fix the noncompliance, where
applicable.
The host is non-compliant if:
The host is not associated to a Host Credential Profile.
The Collect System Inventory on Reboot (CSIOR) feature is disabled or has not been run, which requires a manual reboot.
NOTE: The CSIOR status is not determined when hosts are managed using a chassis.
The SNMP trap destination of the host is not configured to the OMIVV appliance IP address. The failure in SNMP trap destination
setting might be when iDRAC or host credentials that are provided in host credential a profile is invalid. Or, there are no free slots in
iDRAC, or iDRAC Lockdown Mode is turned on—only in iDRAC9-based servers. For the list of iDRAC9-based servers, see the
compatibility matrix.
OMIVV fails to enable the WBEM service on hosts running ESXi 6.5 and later.
The iDRAC firmware version is lower than 2.50.50.50. The iDRAC version 2.50.50.50 or higher is required only to use the system
profile feature.
iDRAC license is not compatible (iDRAC Express is the minimum requirement). The servers without a compatible iDRAC license cannot
be used for monitoring and updating the firmware.
CAUTION:
Even if non-compliant, the hosts in the Lockdown mode are not displayed in the compliance tests. Ensure to
manually check the compliance level. A message is displayed when manually checked. Ignore the message. They do not
display because their compliance status cannot be determined. Ensure to check the compliance of these systems
manually. In such a scenario, a warning message is displayed.
On the Management Compliance page, you can perform the following tasks:
Fix compliance. For more information, see Fix a non-compliant host.
Run inventory. The run inventory job link is active if the iDRAC status is non-compliant or Unknown for any one of the hosts that are
associated to a host credential profile.
Renew iDRAC License. For information, see Fix iDRAC license compliance.
Add OEM hosts. For more information about adding OEM hosts, see Add OEM hosts.
View non-compliant hosts
1. On the OMIVV home page, click Compliance & Deployment > Management Compliance.
A table displays all the non-compliant hosts along with the following information:
Host—The FQDN or IP address of the host
Model—The model name of the server
Credential Profile—The host credential profile name
CSIOR Status—The CSIOR status (ON or OFF). The CSIOR status shows Undetermined for hosts that are managed using
chassis,
SNMP Trap Status—The SNMP Trap Status (Configured or Not Configured).
Hypervisor—The hypervisor name and version
WBEM Status—The WBEM status (Compliant or Non-compliant). The CSIOR status shows Not applicable for hosts that are
managed using chassis.
iDRAC Firmware Version—The iDRAC firmware version
iDRAC License Status—The iDRAC License status (Compliant or Non-compliant).
9
Compliance 59