Users Guide
Available OMIVV appliance version displays wrong
information when the available version is lesser than the
current version
In the OMIVV Admin console, under Appliance Management, Available Virtual Appliance Version displays the modes RPM and OVF
as available.
NOTE: It is recommended that update repository path is set to the latest version and downgrading the virtual appliance
version is not supported.
The 267027 exception is thrown while adding a 12G and
later bare-metal server
During bare-metal discovery, if an incorrect credential is entered, the user account is automatically locked for few minutes. During this
period, iDRAC becomes unresponsive and takes a few minutes before restoring normalcy.
Resolution: Wait for few minutes and retype the user credentials.
During deployment, system profile apply fails due to
iDRAC error
During deployment, OMIVV attempts to create configuration update job in iDRAC. However, the job creation may fail sometimes and
displays a message indicating that a Configuration job is already created.
Resolution: Clear the stale entries and retry the deployment. Log in to iDRAC to clear the jobs.
OMIVV RPM upgrade fails when proxy is configured with
domain user authentication
If OMIVV appliance is configured with proxy to reach the Internet and proxy is authenticated using NTLM authentication, then the RPM
update fails due to the issues in the underlying yum tool.
Version Affected: OMIVV 4.0 and above
Resolution / Work around: Do Back up and Restore to update the OMIVV appliance.
Unable to apply System Profile that has PCIe card in the
FX chassis
The OS deployment fails on a target server if the source server has PCIe card information when using an FX chassis. The System profiles
on the source server have different fc.chassislot ID than the one on the target server. OMIVV tries to deploy the same
fc.chassislot ID on the target server but fails. The System profiles searches for exact instance( FQDD) while applying the profile,
which works successfully on rack servers (identical), but may have few restrictions in modular servers. For example, in FC640, the System
profiles that are created from one modular server cannot be applied on other modular servers in the same FX chassis because of NIC level
restrictions.
Version Affected: 4.1 and later.
Resolution: System profile that is taken from an FC640 server in slot 1 of a FX2s chassis can only be applied on another FC640 server
residing in the slot 1 of another FX2s chassis.
140
Frequently Asked Questions-FAQ