Users Guide
Table 9. Virtualization events (continued)
Event name Description Severity Recommended action
occurred, which requires
additional fans.
The fans are not redundant One of more fans have failed
or have been removed or a
configuration change
occurred, which requires
additional fans
Info Remove and reinstall failed
fans or install additional fans
The fans are not redundant.
Insufficient resources to
maintain normal operations
One of more fans have failed
or have been removed or a
configuration change
occurred, which requires
additional fans
Critical Remove and reinstall failed
fans or install additional fans
The power supplies are
redundant
None Info No action
Power supply redundancy is
lost
The current power
operational mode is non-
redundant because of a
power supply exception, a
power supply inventory
change, or a system power
inventory change. The system
was previously operating in a
power redundant mode
Critical Check the event log for
power supply failures. Review
system configuration and
power consumption
Power supply redundancy is
degraded
The current power
operational mode is non-
redundant because of a
power supply exception, a
power supply inventory
change, or a system power
inventory change. The system
was previously operating in a
power redundant mode
Warning Check the event log for
power supply failures. Review
system configuration and
power consumption
The power supplies are not
redundant
The current power supply
configuration does not meet
the platform requirements to
enable redundancy. If a power
supply fails the system may
shut down.
Info If unintended, review system
configuration and power
consumption and install power
supplies accordingly. Check
power supply status for
failures
The power supplies are not
redundant. Insufficient
resources to maintain normal
operations
The system may power down
or operate in a performance
degraded state
Critical Check the event log for
power supply failures. Review
system configuration and
power consumption and
upgrade or install power
supplies accordingly
Internal Dual SD Module is
redundant
None Info No action
Internal Dual SD Module
redundancy is lost
Either one of the SD card or
both the SD cards are not
functioning properly
Critical Replace the failed SD card
Internal Dual SD Module
redundancy is degraded
Either one of the SD card or
both the SD cards are not
functioning properly
Warning Replace the failed SD card
Manage vCenter settings 97